43
O
pe
ra
tion
Operation
Divisor programming
The pump increases/decreases a stroke rate by the external signal and the divisor. Set a divisor (1-999 pulse
rates) per shot in advance of operation.
NOTE
If a divisor is set to 1, the pump speed equals to the external pulse rate (1:1 operation). This operation, how-
ever, may be upset when the pulse rate has exceeded 360spm and the extra signals are cancelled. Although
this is not malfunction, use of the multiplier is recommended to ensure correct 1:1 operation.
Push the start/stop key to return to the wait state.
"WAIT" indication appears.
Use the UP or DOWN key to adjust stroke rate (MAN speed).
• The stroke rate increases/decreases every time
the UP or DOWN key is pushed.
• Press and hold either key for three seconds
for quick change. Quick change stops at 1 or
360spm. 1 or 360spm skips to 360 or 1spm
when the key is released and pushed once.
Push the UP key while pressing the EXT key to call up the Digital/Analog selection.
"dIG"(digital) or "ANA"(analog) will appear.
Select "dIG".
Scroll through "dIG" and "ANA" by the UP
and DOWN keys.
2
1
3
4
or