- 17 -
10-3. Wiring
The power source handling during wiring work must be done by a
licensed electric specialist only. Iwaki will not be responsible for
any accident or mechanical damage if such an accident or damage
results from the user's failure to observe the instructions above. For
more information on wiring by a specialist, contact your dealer.
■ Before wiring
[1]
Be sure to confirm before wiring that the main power supply is
turned off (power supply is disconnected).
[2]
Wiring shall be done in accordance with the local electric work
regulations. (Use high-quality wiring elements and carry out
wiring in accordance with the technical standards of electrical
installation and related interior wiring rules.
[3]
Use the power source voltage indicated on the "Specifications"
label.
[4]
The pump is not provided with an ON/OFF switch. The pump
starts operation when power is supplied by connecting the power
cable of the pump with the power source.
[5]
Make sure to include a ground
wire in the wiring. Select a
well-ventilated place for pump
installation. The pump must
not be allowed to become wet or
damp with splashed water.
[6] If the pump is installed with an earth leakage breaker and the
breaker is activated, eliminate the cause of the breaker activation
first, before resetting the condition. When checking the pump
for the said cause, be sure to turn off the power supply.
● AC115V
● AC220~240V
Wiring diagram
Black
White
Green
Thermal protector
Power source
Auxiliary coil
Capacitor
Main coil
Electrical Shock
Brown
Blue
Yellow/Green
Thermal protector
Power source
Auxiliary coil
Capacitor
Main coil