- 4 -
4. Pump Identification Codes
MDG - R 2 R V A 230 - 01
(1) (2) (3) (4) (5) (6)
(7)
(1)
Pump model
(2)
Nominal discharge
2:0.7ml/rev
(3)
Liquid temperature
R: 0~50deg.C
B: 0~95deg.C
(4)
Relief valve
No code: without relief valve
V: with relief valve
(5)
Connection
A: Rc 1/8
B: 1/8 NPT
C: G 1/4
(6)
Line voltage
100: AC100V
115: AC115V
230: AC220~240V
24: DC24V
24H: DC24V
(7)
Non-standard specification code
01~99: Non-standard
No code: Standard
4-1. Specification
50/60Hz
Model
Max.
discharge
capacity
(l/min)
Max.
discharge
pressure
(Mpa)
Attainable
vacuum
(Kpa)
Rated
speed
(rpm)
Motor specification
Mass
(kgf)
Rated
voltage
(V)
Rated
current
(A)
MDG-R2RV( )100
1.8/2.1
0.3
5.33
2600/
3200
AC100
0.5/0.5
2.1
MDG-R2RV( )115
AC115
0.45/0.45
MDG-R2RV( )230
AC220-240
0.25/0.26
MDG-R2BV( )100
1.6/1.9
AC100
0.5/0.5
MDG-R2BV( )115
AC115
0.45/0.45
MDG-R2BV( )230
AC220-240
0.25/0.26
MDG-R2B( )100
AC100
0.5/0.5
MDG-R2B( )115
AC115
0.45/0.45
MDG-R2B( )230
AC220-240
0.25/0.26
MDG-R2B( )24
1.7
0.15
2800
DC24
1.0
1.1
MDG-R2RV( )24H
1.8
0.3
2000
1.2
MDG-R2B( )24H
1.7
Note 1. The above performance is based on operation with clean water at 25deg.C.
(The max discharge capacity changes depending on the temperature of the liquid
used. Further information is available on request.)
2. The max allowable liquid viscosity is 50mPa
•
s for the pumps with an AC motor and
10mPa
•
s for the pumps with a DC motor.
3. The allowable ambient temperature is 0-40deg.C.
4. The MDG-R2( )V pump is equipped with a built-in relief valve.
5. Maximum operating noise is 55dB or below.
(0.5m away from the front of a pump, A scale)