67
Chapter 2
••
Emergency System Backup
Battery Backup
If full system operation is required during a power failure, rechargeable gel cell
backup batteries must be connected to the power supply. Backup batteries are charged while the
system is powered up. In the event of a power failure, the batteries will prevent a system shutdown.
The voltage of the batteries connected to the power supply must be between 19.0 VDC and 27.3
VDC.
Important!
To reduce the risk of fire or injury, follow the instructions listed below:
■
Use only a GS Battery model PE-12V0.8 or PE-12V7 sealed battery that was tested for UL
safety. (
Contact Authorized Distributor, Advanced Battery Systems, LLC, at 1-800-227-7090 and refer to Iwatsu ADIX-VS.)
■
Do not dispose of the batteries by burning, the cell may explode. Check with local codes for
special disposal instructions.
■
Do not open or mutilate the batteries. Released electrolyte is a corrosive and may cause injury
to the eyes or skin. It is toxic if swallowed.
■
Handle the batteries with care to avoid shorting the battery by touching conducting materials
such as rings, bracelets, screwdrivers and pliers.
■
Charge the batteries in accordance with the instructions and limitations specified on page 32.
■
Observe proper polarity orientation between the batteries and battery charger.
■
Do not mix used and new batteries in this product.
■
Do not mix batteries of different sizes or from different manufacturers in this product.
The table below lists the backup power consumption of the individual ADIX-VS components. Use it
as a guide to determine the quantity of backup batteries needed.
Summary of Contents for ADIX VS
Page 1: ...Technical Manual...
Page 2: ...ADIX VS...
Page 3: ...Technical Manual...
Page 8: ...iv ADIX VS...
Page 9: ...Section 1 ADIX VS Introduction...
Page 10: ...097 098 099 100...
Page 14: ...ADIX VS Technical Manual Section 1 Introduction 4...
Page 34: ...ADIX VS Technical Manual Section 1 Introduction 24...
Page 35: ...25 Section 2 ADIX VS Hardware...
Page 36: ...ADIX VS Technical Manual Section 1 Introduction 26 097 098 099 100...
Page 71: ...61 Section 3 ADIX VS Installation...
Page 72: ...ADIX VS Technical Manual Section 3 ADIX VS Installation 62 097 098 099 100...
Page 76: ...ADIX VS Technical Manual Section 3 ADIX VS Installation 66...
Page 80: ...ADIX VS Technical Manual Section 3 ADIX VS Installation 70...
Page 112: ...ADIX VS Technical Manual Section 3 ADIX VS Installation 102...
Page 113: ...103 Section 4 ADIX VS Programming...
Page 114: ...ADIX VS Technical Manual Section 4 ADIX VS Programming 104 097 098 099 100...
Page 122: ...ADIX VS Technical Manual Section 4 ADIX VS Programming 112...
Page 124: ...ADIX VS Technical Manual Section 4 ADIX VS Programming 114...
Page 134: ...ADIX VS Technical Manual Section 5 ADIX VS Feature Enhancements 124...
Page 135: ...ADIX VS...