Environmental Characteristics
3.2.1
Environmental Specification
The below table provides the Environment specification of RZ/G1C SBC.
Table 16: Environmental Specification
Parameters
Min
Max
Operating temperature range
1,2
-20°C
+85°C
Humidity
–
Operating
3
-
95%RH
¹ iWave guarantees the component selection for the given operating temperature. The operating temperature at the
system level will be affected by the various system components like system enclosure, air circulation in the system,
system power supply etc. Based on the system design, specific heat dissipating approach might be required from
system to system. It is recommended to do the necessary system level thermal simulation and find necessary thermal
solution in the system before using this board in the end application.
² If CVBS Input RCA Jack is not supported in RZ/G1C SBC, then operating temperature range is -25°C to 85°C.
3
To meet this humidity specification, conformal coating needs to be done on the board. By default, iWave boards
doesn’t come with conformal coating. Please contact iWave to support conformal coating.
3.2.2
RoHS Compliance
iWave’s
RZ/G1C SBC is designed by using RoHS compliant components and manufactured on lead free production
process.
3.2.3
Electrostatic Discharge
iWave’s
RZ/G1C SBC is sensitive to electro static discharge and so high voltages caused by static electricity could
damage some of the devices on board. It is packed with necessary protection while shipping. Do not open or use the
SBC except at an electrostatic free workstation.