EN
3.
Operation
3-1. Control Panel
A
Wire inspection key. Press this key to feed wire quickly and release the key to stop feeding.
B
The left knob is used to adjust the parameters of C, D, E, and F
C
Indicator of wire feeding speed, facilitating to set the feeding speed (m/min).
D
Indicate the set welding current and the actual current during welding.
E
Indicator of thickness of workpiece plate, facilitating to set the thickness (mm) and relevant
parameters can be automatically adjusted.
F
Indicator of secondary menu to indicate other parameters not on the panel.
G
Selection keys of display parameters, which can display the parameters of C, D, E, and F
(right) and I, J, K, L and M (right) indicators.
H
Data display, which displays the set value, actual parameters and other information.
I
Indicate the set arc length and the negative value indicates the short arc.
J
Indicator of inductance/arc force, different welding modes (metal transfer, arc spray force
and arc stiffness) have different function.
K
Display the voltage value.
L
JOB indicator, which displays the current job No.. Rotate the voltage parameters knob to
relevant JOB. It also displays the storage channel, which can be changed by regulating
the right knob. Short press the storage call key to call the parameters of corresponding
channels. Long press the storage call key to store relevant parameters to corresponding
channel No..
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
9
8