EOMs Operating Manual
Ref. Ed. 0
–
08/02/2021
14
2.1.4
E
LECTROSTATIC
D
ISCHARGE
(ESD)
Although the RF port has been tested Class 2 and the DC port Class 0 (MIL-STD-750E Method
1020.2), care must be taken to prevent ESD and other electrical stresses. Otherwise, delicate
electrical structures inside the package could be damaged.
•
We recommend unpacking or packing EOM in an Electrostatic Protected Area (EPA).
•
Applying a transient overvoltage or any voltage above the specified maximum may cause a
permanent damage to the modulator.
2.2
Maximum ratings
•
Check optical, electrical, environmental maximum ratings available on our website.
•
We strongly recommend splicing the fibers and avoid optical connectors when operating at
high optical power levels (>100mW) and short wavelengths (1060 nm, 800 nm).