OCEANO RT2500S/RT5000S Series – User Guide
System:
RT8x1
Preventive Maintenance
Sub-system
:
Reference:
PM05
Page:
3/5
Subject: Testing after Closure
Maintenance level: 2
Frequency: after each closure
Duration:
30 minutes
With OCEANO RT2500 S-Universal and OCEANO RT2500S Side bar models, manually
re-arm the release mechanism.
Part 5 – PINGER mode
Step
Action
1.
Choose the
PINGER ON
code as the CMD code.
2.
Proceed through step
1
(use
Pinger ON
as command type and PFR receive frequency)
and go to step
2
.
The device transmits two CAF pulses and turns into the free running acoustic transmitter
mode at PFR frequency. TT801 displays the pinger rate.
3.
To switch the Pinger mode off, repeat the step 5, replacing PINGER ON settings by
PINGER OFF and use Other CMD as type of command.
4.
Acoustic device should stop the free running transmitting mode
5.
End of procedure
Part 6 – DIAGNOSTIC mode
Step
Action
1.
Choose the
DIAGNOSTIC
code as the CMD code.
2.
Proceed through step
1
(use
Telemetry
as command type and PFR receive frequency)
and go to step
2
.
The RT8x1 returns to the TT801 two CAF pulses that transmit information about voltage
of the main battery pack and verticality indication posted up on the TT801 display.
3.
End of procedure
Vertical position means that the main axis of the acoustic transponder housing is vertical,
with the upper end plate looking upwards. Check once again all the acoustic transponder
functions.
Procedure
Procedure
MU–RT8x1–AN–001 Ed. M – September 2013