SeapiX
–
Installation Manual
SSD-C-1306 Ed. A
–
01/2020
35
Step
Action
4.
Pass the transducer cable through the hull. To tighten it and ensure watertightness, use
iXblue-delivered cable gland: refer to plans PLA05712 AA and PLA06149 AA.
Caution
The installation of the cable gland and its qualification are under the shipyard/customer
responsability. The cable gland delivered has been designed for steel hull configuration.
5.
Connect the transducer cable onto the SAU; screw it completely but without forcing.
Refer to plan 00162207-A and to 4.2.1 Transducer Cable
to have
information on the authorized bending radius and the connector
s’ lubrication and
screwing
.
6.
Clip the cable into the SAU clipping device then attach it with tie-wraps all along the
compartment to prevent excessive movement during operations.
Cable gland
Transducer
cable