4.4.5
P
OLE
-M
OUNTING AN
SAU
S
TEP BY
S
TEP
Step
Action
1.
Position the plastic ring on the SAU and screw it: refer to PLA02664 AG
2.
Check the orientation of the SAU: the indicator located on the SAU rear side shall be
pointing towards the bow. There is also a fluorescent arrow on the SAU front face.
3.
Connect the transducer cable:
•
refer to plan 00162207-A and to 4.2.1 Transducer Cable
to have
information on the authorized bending radius and the connector
s’ lubrication.
•
Screw it completely without forcing.
4.
Using brackets, fix the SAU to the interface.
5.
Let the transducer cable run through the pole and attach the interface to the pole.
Steps 4 and 5 are not under iXblue responsability.