Float Assembly
- The float assembly connects to
the core unit in one location. There is no adjustment
necessary for setting the dish depth.
The float assembly is bolted to the core unit of
the GridBee to allow the distributor dish lip to be
automatically set to the correct depth below the surface
of the water. The depth may vary depending on hose
length being supported by the machine and the amount
of hose resting on the bottom of the reservoir due to
fluctuations of the water.
Each float tube is connected to the central machine
structure with 1 bolt. Each float is connected to
the float tube by one pin. Each float assembly is
constructed of the molded float and float tube. The
end of the float tube contacts the core unit frame when
the float is extended into place by means of boyancy
pressure when deployed into the water.
If the machine is resting in the bottom of an empty tank,
the GridBee will be supported against the floats resting
on the floor of the tank. Once water is brought back
into the tank, the machine will self deploy and begin to
float.
Float Connection Points
Bolt
3/4 in to 1 in
(2.0 cm - 2.5 cm)
Distance Between Distributor Dish And Water
Level
CAUTION: DO NOT REMOVE ANY FLOAT
ASSEMBLY PINS OR BOLTS WHILE THE
GridBee IS FLOATING IN THE WATER!
THE GridBee MUST BE RESTING ON THE
GROUND OR SAFELY SUPPORTED TO
RELIEVE THE FORCES ON THE FLOAT
ASSEMBLY STRUCTURES PRIOR TO
DISASSEMBLY! FAILURE TO FOLLOW
THIS WARNING COULD LEAD TO SINKING
THE GridBee, SERIOUS INJURY!
Eye Loop