Core Unit Disassembly (Cont.)
STEP 1:
First identify the Core Unit Assembly
Components shown to the right.
STEP 2:
Remove the three M12 Bolts holding
the Tri-Frame to the Lower Core Unit Legs and
remove the Tri-Frame from the Core Unit by lifting
upward.
STEP 3:
On the same half of the Split Dish,
remove four of the M8 Bolts for each Split Dish
Flat to separate the Lower Core Unit into two
halves. The Split Dish Flats can remain connected
to one half as long as the hatch opening is large
enough.
STEP 4:
The Core Unit Assembly is now broken
down into it's smallest form and each component
will fit through a hatch with clear, unobstructed
opening of at least 3 feet X 3 feet (0.92m X
0.92m).
STEP 5:
Once these components are lowered
through the hatch, they can be reassembled using
the opposite order of STEPS 1-4.
Impeller Reinsertion
STEP 1:
Place impeller assembly back in place
(Slide lower coupling into upper coupling and
allow to drop down into place). Be sure bottom of
impeller shaft fits into the bushing in the dish and
that the coupling sleeve is in place inside the shaft
coupling assembly.
STEP 2:
Place clevis pin back through upper shaft
coupling and secure with hair pin.
Impeller Assembly Reinsertion Motion
©2022 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | watercare@ixom.com
Equipment Assembly
458_10264_20220110
O&M_SB5000PW_10272_20220119 - 16