background image

 

19

 

Summary of Contents for ATMOSPHERE

Page 1: ...490 rue de l Argon Quebec Qc CANADA G2N 2C9 Phone 418 849 8095 Fax 418 849 0077 www jaroby com ATMOSPHERE WOOD STOVE June 1st 2013 Reviewed ATMOSPHERE Conforms to UL Std 1482 Certified to ULC Std S627...

Page 2: ...ND THERMODISC 13 PREVENTIVE MEASURES AND MAINTENANCE 14 INTERCHANGEABLE PARTS LIST 15 INSTALLATION OF THE FIREBRICKS 16 WARRANTY 17 READ CAREFULLY THIS MANUAL AND KEEP IT FOR FURTHER REFERENCES INSTAL...

Page 3: ...ILE IN OPERATION DO NOT TOUCH KEEP CHILDREN CLOTHING AND FURNITURE AVAY FROM STOVE CONTACT MAY CAUSE SKIN BURNS SEE NAMEPLATE AND INSTRUCTIONS Never let the appliance without supervision when the door...

Page 4: ...near the appliance You should contact your municipal or provincial fire department to have knowledge of the procedure to be followed in case of a chimney fire Think of an emergency plan In case of a...

Page 5: ...he doors in order to ensure good ventilation This special paint is conceived to tolerate temperatures until 1200 F 650 C CREOSOTE The wood burning slowly produces tar and other organic steams which fo...

Page 6: ...7m 12ft 3 7m Exterior height 42 106 7cm 32 6 73 7cm Exterior width 26 67 3cm 26 67 3cm Exterior depth 26 66cm 26 66cm Door opening 16 X 10 40 6cm X 26 7cm 16 X 10 40 6cm X 26 7cm Interior height 13 33...

Page 7: ...n 2 You must install a fireproof plate under the appliance which must exceed of 18 inches at the front and of 8 inches at each side 3 The free space shall not be reduced except under the approval of t...

Page 8: ...s or the CAN CSA B365 ULC S635 ULC S640 norms For the chimney follow the chimney manufacturer s instructions EXTERIOR VERTICAL INSTALLATION The Atmosphere EPA must be installed in accordance with the...

Page 9: ...LLATION ON A CATHEDRAL ROOF The Atmosphere EPA must be installed in accordance with the applicable local laws or the CAN CSA B365 ULC S635 ULC S640 norms For the chimney follow the chimney manufacture...

Page 10: ...CAN CSA B365 ULC S635 ULC S640 norms For the chimney follow the chimney manufacturer s instructions VERTICAL INSTALLATION The Atmosphere EPA must be installed in accordance with the applicable local l...

Page 11: ...your decoration by its originality and its heat It requires only 8 inches of clearance to the back and 12 inches of the sidewalls with the addition of one heat shield when the installation is made wi...

Page 12: ...endations you are ready for the lighting 1 Place papers and small wood in the appliance 2 Before lighting be sure that the chimney is warm enough 3 When the fire is well lit gradually add bigger wood...

Page 13: ...nction the heat reaching a temperature of 120o F activates the thermo disc At this moment the thermo disc activates the fans for a better distribution of heat in your home As soon as the heat goes und...

Page 14: ...ot use a paper towel to clean gildings If they are not erased before the first fire fingerprints and other marks could stain these surfaces permanently 7 The Atmosphere is provided with an ashtray und...

Page 15: ...15 INTERCHANGEABLE PARTS LIST BRICKS WOOL CAP PLATES USED TO RETAIN WOOL PIPES GLASSES DOOR S HANDLE APPLIANCE S DOOR FANS CORDS TO ORDER PARTS PLEASE CONTACT YOUR AUTHORIZED RETAILER...

Page 16: ...ports of the back wall and of the side walls are partially screwed 2 Second install the bricks on the side walls and the back wall A 2 B 6 D 4 F 2 and tighten the screw to fix the bricks 3 File the fo...

Page 17: ...warranty repair are not covered The manufacturer may at its discretion decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discre...

Page 18: ...18 1 Digital pictures required 2 Shipping cost are not covered outside CANADA Review oct 2014...

Page 19: ...19...

Reviews: