November 5, 2015
12
General stove installation steps
1) Read the entire owner and installation manual before
install and use your stove.
2) Chose a spot where to install your cook stove. Read
section about floor protection dimension and about
localisation of stove over the floor protection plate, and
for combustible material clearance. Once you have
decided where to install the stove, mark the roof at the
center of chimney
•
To be sure that the vertical center of the chimney
is set, use a plumb line and mark the center on the
floor.
3) Verify if it is possible to pass chimney without
damaging the structural integrity of your house. If not,
you might have to change the location of the stove
while keeping the minimum clearance. In case that you
have to cut a beam, be sure to keep the structural
integrity of your house by following state of the art and
National building code.
•
We recommend to have this appliance installed by
a certified installer.
Note:
This appliance have to be connected to 6 inch (15.24 cm)
factory build chimney HT UL 103 or CAN/ULC S629
compliant or a 6 inch (15.24 cm) masonry chimney with a
homologated sleeve inside.
4) Install the chimney following the manufacturer
instruction.
5) Place the stove directly on the floor aligned vertically
with the center of chimney, and trace the 4 sides of the
stove on the floor and remove it.
6) Trace the dimension of floor protection. Keep the offset
clearance of 8 inches (20.3 cm) from the side and the
back of the stove. The front offset clearance from the
door opening is 16 inches (40.6 cm) in US and 18
inches (45 cm) in Canada.
7) Install the floor protection plate inside the trace. (It must
be non-combustible material)
8) Put the stove on the protection floor plate and respect
the offset clearance set at step 6. Be sure to centering
chimney with the chimney collar.
9) If you have an outside air inlet, you must use 4 inch
(10.16 cm) flexible aluminum pipe. The pipe must be
hermetic toward outside with an air inlet and an
approved grid.
10) Install the chimney connector from the stove. It is
necessary to attach the each pipe section with 3
screws from the stove collar to the chimney collar.
Note:
•
The single wall or double wall chimney connector
must be 6 inch diameter and have a minimum
thickness of 24 gauge (0.025 inch, 0.64 mm)
•
Do not use galvanised steel chimney connector.
.