PR_I017/2023-01-23-EN
12
Minimums clearances to combustible material
With these reduced clearances, this appliance takes a minimum
space to be installed. Whether in the living room or the dining
room, this appliance will complete your decorate by his
originality and heating
.
It requires a minimum clearance of 16
3/4 inches (42.5 cm) to the back of the top of the stove
. For a
single wall in Canada, the minimum clearance between
smoke pipe and wall must be 18 inches (45.7cm).
For a
single wall pipe in the USA
, the clearance to the wall
until the back of stove is
13 inches (33cm).
For a double wall pipe, the back clearance is 11 1/4 inches (28.6
cm).
The MINIMUM side clearance for a stove
with side shield
is 16
inches (40.6cm) and for a stove
without side shield
the
clearance is 23 inches (58.4 cm).
➢
For a 45° corner or other corner installation, the
minimum clearance between the stove (
with side
shield
) and combustible material must be 8 3/4 inches
(22.2 cm) and from the pipe is 17 inches (43.2 cm) for
the USA
➢
For the
CANADA
, the clearance
with shield
must be
9 3/4 inches (24.8cm) from the combustible
material and 18 inches (45.7cm) from the pipe.
➢
. For a 45° corner or other corner installation, the
minimum clearance between the stove (
without side
shield
) and combustible material must be 15 3/4
inches (40 cm) and from the pipe is 24 inches (61.1cm)
➢
➢
To know how to reduce that dimension, you have to
contact your local authority for installing heat shield on a
wall. The Installation with reduced clearances must
comply with standard NFPA211 or CAN/CSA-B365.
Summary of Contents for PIONEER
Page 4: ...PR_I017 2023 01 23 EN 4 RATING PLATE...
Page 5: ...PR_I017 2023 01 23 EN 5 APPLIANCE DIMENSION...
Page 6: ...PR_I017 2023 01 23 EN 6...
Page 7: ...PR_I017 2023 01 23 EN 7...
Page 34: ...PR_I017 2023 01 23 EN 34 ANNEX 1 Exploded diagram of door Arc door...
Page 35: ...PR_I017 2023 01 23 EN 35 ANNEX 2 Fans electric wiring diagram...