GENERAL STOVE INSTALLATION STEPS

Location considerations 

We  recommend  installation  of  this  appliance  by  a  certified 
installer. 

Consideration must be given to: 

  Safety; 

  Traffic flow; 

  Convenience; 

  Chimney and chimney connector required; 

  Draft. 

Drawing your installation plan on paper is a good way to avoid 
mistake.  

THESE 

STOVE 

MODELS 

ARE 

NOT 

APPROVED TO INSTALL IN AN ALCOVE 

Write on the plan: 

 

Exact  dimensions  for  clearances  to  combustible 
material; 

 

Exact dimensions of the floor protection; 

 

Measurements of the chimney location. (If it not already 
installed. Be sure to have all clearances recommended 
by  the  factory-built  chimney  manufacturer  to  pass 
through the ceiling and roof). 

We  recommend  that  a  qualified  building  inspector  and  your 
insurance company representative review your plan before and 
after installation. 

 

General steps of installation 

1)  Read  the  entire  installation  manual  before  installing 

and using your stove. 

2)  Choose  a  spot  where  to  install  your  stove.  Read 

section about floor protection dimension, localisation of 
stove  over  the  floor  protection  plate  and  combustible 
material clearance.  Once  you  have  decided  where  to 
install the stove, mark the roof at the center of chimney. 

o

  To be sure that the vertical center of the chimney, 

use a plumb line and mark the center on the floor. 

3)  Check if it possible to pass chimney without damaging 

the structural integrity of your house. If so, you have to 
move  the  location  of  the  stove  while  keeping  the 
minimum  clearance  or  more  to  be  sure.  If  you  can’t 
move the stove and have to cut through a beam, make 
sure  to  keep  the  structural  integrity  of  your  house  by 
following state of the art and National building code.  

o

 

We recommend installation of this appliance by a 
certified installer. 

 

Note

This  appliance  have  to  be  connected  to  6  inches 

(15.24 cm) factory build chimney HT UL 103 or CAN/ULC 
S629 compliant or a 6 inches (15.24 cm) masonry chimney 
with  a  homologated  sleeve  inside.  Do  not  install  the 
chimney directly  at  the outlet of  the  appliance.  A chimney 
connector  (flue  pipe)  is  required  unless  the  appliance  is 
specifically approved for that type of installation.

 

 
4)  Install  the  chimney  following  the  manufacturer 

instruction. 

5)  Put the stove directly on the floor aligned vertically with 

the center of chimney, and trace the side of the stove 
on the floor and remove it. 

6)  Trace  the  dimension  of  protection  plate  on  the  floor. 

There must be 8 inch (20.3 cm) clearance from the side 
and the back of the stove. . From the front of the door 
opening, there must be a clearance of 16 inches (40.6 
cm)  in  US  and  18  inches  (45  cm)  in  Canada.  If  the 
space  heater  meeting  the  requirement  of  CAN/ULC 
S627 is suitable for installation on a combustible floor 
and do not require radiant floor protection.  

7)  Install the floor protection plate inside the mark (It must 

be non-combustible).  

8)  Put the stove on the protection floor plate and respect 

the offset clearance set at step 6. Be sure to center the 
stove  under  the  chimney.  We  recommend  to  fix  the 
stove  to  the  floor  with  bolt  in  the  slot  made  for  this 
purpose in the legs. In a mobile home, it is obliged to 
fix the stove. 

9)  If you have an outside air inlet, you must use 4 inches 

(10.16  cm)  flexible  aluminum  pipe.  The  pipe  must  be 
sealed with thermal resistant sealant and it has an air 
intake with grate approved for this purpose. 

10)  Install  the  chimney  connector  on  the  stove.  The  pipe 

must be fixed with at least 3 screws on the stove collar, 
each chimney connector and the chimney collar. 

Note

The single wall chimney connector must be 6 inches 

diameter and have a minimum thickness of 24 gauge (0.025 
inches  0.64  mm).  Do  not  use  galvanised  steel  chimney 
connector. 

.

Summary of Contents for PIONEER

Page 1: ...T RESTRICTION AND INSTALLATION INSPECTION IN YOUR AREA Instruction Manual PLEASE READ CAREFULLY AND KEEP THIS MANUAL FOR FUTURE REFERENCE 490 rue de l Argon Qu bec CANADA G2N 2C9 T l 418 849 8095 Fax...

Page 2: ...nstallation 21 Transportable building installation 22 Chimney installation General steps 23 Inside Masonry Chimney Vertical Installation 24 Outside Vertical Installation 24 Cathedral Vertical Installa...

Page 3: ...d on the floor Do not install in a sleeping room Exterior air inlet is mandatory for mobile home use All roof chimney termination shall be able to be readily removed at or below an elevation of 13 1 2...

Page 4: ...PR_I017 2023 01 23 EN 4 RATING PLATE...

Page 5: ...PR_I017 2023 01 23 EN 5 APPLIANCE DIMENSION...

Page 6: ...PR_I017 2023 01 23 EN 6...

Page 7: ...PR_I017 2023 01 23 EN 7...

Page 8: ...cm Exterior Depth 33 5 8 in 85 6 cm 33 5 8 in 85 6 cm 34 1 4 in 87 cm 33 5 8 in 85 6 cm Door Opening 15 1 8 in x 9 1 4 in 38 4 cm x 23 5 cm 15 1 8 in x 9 1 4 in 38 4 cm x 23 5 cm 15 1 8 in x 9 1 4 in...

Page 9: ...ior Depth 33 5 8 in 85 6 cm 34 3 8 in 87 3 cm 34 3 8 in 87 3 cm 36 1 4 in 91 9 cm Door Opening 15 1 8 in x 9 1 4 in 38 4 cm x 23 5 cm 15 1 8 in x 9 1 4 in 38 4 cm x 23 5 cm 15 1 8 in x 9 1 4 in 38 4 c...

Page 10: ...m 16 inches 40 6 cm Front 48 inches 121 9 cm 48 inches 121 9 cm 48 inches 121 9 cm 48 inches 121 9 cm Minimum Ceiling height 84 inches 213 4 cm 84 inches 213 4 cm 84 inches 213 4 cm 84 inches 213 4 cm...

Page 11: ...fuels e g Charcoal and possibilities of generating carbon monoxide and the hazards from carbon monoxides When the smoke detector is activated is mean that the smoke spill out of the appliance Verify...

Page 12: ...for a stove with side shield is 16 inches 40 6cm and for a stove without side shield the clearance is 23 inches 58 4 cm For a 45 corner or other corner installation the minimum clearance between the...

Page 13: ...rated and secure it with nut lock washer and washer 2 3 4 Attention Be sure the legs are in place correctly positioned and in contact with the bottom of the stove Fan and Snap disc box installation Th...

Page 14: ...ONT OF THE APPLIANCE When it s ON the snap disc will start at the moment when the temperature of ventilation box gets 120 Fahrenheit 49 Celsius DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DIS...

Page 15: ...ke double pipe For the smoke simple pipe it s not necessary to remove the pre cut metal part For the double smoke pipe you need to remove the pre cut metal part See blue arrow below Put the smoke pipe...

Page 16: ...firebrick installation Put 8 bricks A on the back wall and fix with a screw and brick support Floor firebricks installation Put 4 Bricks A near to the back wall and 2 bricks P in front of bricks A Fl...

Page 17: ...eel parts on the rockwool as illustrated 1 Put 3 A bricks over the two top pipes and push them against the back bricks Be sure to eliminate any space between the back bricks and the bricks you install...

Page 18: ...ration and parts without ash plug 1 2 half disk metal steel plates 2 1 rock wool insulating blanket 3 3 3 4 x 15 pipes with holes on a single side 4 2 3 4 x 15 pipes with bigger holes on both side 5 1...

Page 19: ...d list of parts with ash plug 1 2 half disk metal steel plates 2 1 rock wool insulating blanket 3 3 3 4 x 15 pipes with holes on a single side 4 2 3 4 x 15 pipes with bigger holes on both side 5 1 scr...

Page 20: ...nce by a certified installer Note This appliance have to be connected to 6 inches 15 24 cm factory build chimney HT UL 103 or CAN ULC S629 compliant or a 6 inches 15 24 cm masonry chimney with a homol...

Page 21: ...earances and inclinations of the horizontal sections and verify if you have all the necessary parts for the final installation o For direct vertical installation you will need 1 vertical section of 24...

Page 22: ...stance of 4 inches 10 2 cm or more in order to avoid contact with chimney f The chimney must exceed at least 3 feet 91 4 cm from the highest point of opening made in the roof and exceed also 2 feet fr...

Page 23: ...installation method Always refer to the manufacturer s manual of the chimney for a more detailed method for your chimney 1 Determine the total length needed for your chimney 2 Cut the holes into all...

Page 24: ...re of the manner you have to To install the stove onto an abandoned masonry fireplace and use the good condition masonry chimney the chimney must have inside a certified metallic sleeve cover up all t...

Page 25: ...e with the applicable local laws or the CAN CSA B365 NFPA211 USA norms Follow the chimney manufacturer s instructions to install the chimney Always pass chimney between joists If a joist need to be cu...

Page 26: ...certified Installer Always frame around chimney Keep minimal clearances written into your chimney manual Do not fill the gap between the fire stop and the chimney Nothing must be in contact with the c...

Page 27: ...ntake box Insert the pipe into the hole and screw the pipe using the 3 holes in the tabs Put a generous layer of high temperature latex caulking onto the joint to ensure the pipe is sealed 2 Cut the e...

Page 28: ...re 2 type of tubes used into the stove Three of them are single side perforated 1 and are in the back of the heat chamber The 2 tubes in front of the heat chamber are double side perforated tube 2 How...

Page 29: ...O Disc Low burn rate From the high burn rate coal bed when 5 to 6 lbs left the load can be inserted in the firebox Open the door Insert the 36 lbs 16 3 Kg load in the wood heater Close the door immedi...

Page 30: ...rewood over the ember keeping it away from the glass door to avoid flame touching the ceramic glass ATTENTION DO NOT OVER CHARGE THE STOVE OVER THE UPPER BRICK DO NOT BUILD A FIRE NEAR THE WINDOW THIS...

Page 31: ...ent draft will cause the appliance to leak smoke into the room through appliance and chimney connector joints MAINTENANCE Ash Removal The wood burning doesn t transform the wood into combustion gas co...

Page 32: ...ng chimney also requires to climb on the roof to remove the chimney cap and sometime even a very high chimney section too We recommend to call a Professional chimney Sweeper certified by APC in Quebec...

Page 33: ...m braided fiberglass rope To install the new fiberglass rope we recommend to detach the door from the stove Please see the pertinent section in this manual Fiberglass rope preparation 1 Take the end o...

Page 34: ...PR_I017 2023 01 23 EN 34 ANNEX 1 Exploded diagram of door Arc door...

Page 35: ...PR_I017 2023 01 23 EN 35 ANNEX 2 Fans electric wiring diagram...

Page 36: ...3 Parts that can be replaced Bricks Door glass Spring Handle Stove Door with handle Fans Flat fiber glass rope around glass Round fiberglass rope Ash Plug Slotted Brick Washer Call your stove seller...

Page 37: ...t or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted p...

Reviews: