PR_I017/2023-01-23-EN
22
Transportable building installation
DANGER: DO NOT INSTALL IN BEDROOM.
WARNING: THE STRUCTURAL INTEGRITY OF THE MOBILE
HOME FLOOR, WALL, AND CEILING/ROOF MUST BE
MAINTAINED.
VAPOR BARRIER EFFICACITY MUST BE KEEPT IN GOOD
CONDITION.
1) Do the General stove installation from steps 1 to 11.
2) The following requirements are MANDATORY for
installation in a transportable building.
a. The stove must be fixed on the floor of mobile
home with screws and washers.
b. The exterior air intake must be installed.
c. The stove must be electrically-grounded to
chassis of the mobile home. In USA, electrical
grounding to the certified terminals with 8 gauge
wire and using star washer are mandatory.
d. All of the following equipment must be certified
and approved for mobile home installation.
•
The chimney system;
•
The roof flashing;
•
The Storm collar;
•
Cap with spark arrester;
•
Firewall;
•
Chimney ceiling support;
•
Decorative collar.
e. If the chimney is exposed outside from a wall and
placed lower than 7 feet (213 cm) above the
ground level where the mobile home is situated, a
shield must be installed around the chimney from
the bottom to 7 feet (213 cm) high. If openings are
made into the shield, they must be less than ¾
inch (2 cm) wide and keep the distance of 4 inches
(10,2 cm) or more in order to avoid contact with
chimney.
f.
The chimney must exceed at least 3 feet (91,4 cm)
from the highest point of opening made in the roof
and exceed also 2 feet from the highest point of
the roof which is 10 feet away from the chimney.
g. Be sure to seal correctly the flashing of the roof,
the firewall and the exterior air inlet with sealant.
You should also pay attention to the efficacy of
vapor barrier.
3) Always keep the door closed. Open it only when add
wood or start fire.
4) To close the exterior air inlet when the stove is not in
use, a damper must be installed in the air intake pipe.
5)
Don’t forget to open the damper when operate your
stove so that the smoke will not enter the house.
6) Always use certified parts for mobile home. Never use
a substitute
The chimney shall be provided with a spark arrester
secured to the chimney. The net free area of the arrester
above the chimney outlet shall be not less than four times
the net area of the chimney outlet, and the vertical height of
the arrester above the chimney outlet shall be not less than
one-half the diameter of the chimney flue. Opening shall not
permit the passage of a sphere having a diameter larger
than ½ inch (12.7mm) and shall permit the passage of a
sphere having a diameter of 3/8 inch (9.6mm)
When the space heater is installed in a transportable
building, you need to remove the chimney for
transportation.
Exterior Kit number:
ECPAE
.
Summary of Contents for PIONEER
Page 4: ...PR_I017 2023 01 23 EN 4 RATING PLATE...
Page 5: ...PR_I017 2023 01 23 EN 5 APPLIANCE DIMENSION...
Page 6: ...PR_I017 2023 01 23 EN 6...
Page 7: ...PR_I017 2023 01 23 EN 7...
Page 34: ...PR_I017 2023 01 23 EN 34 ANNEX 1 Exploded diagram of door Arc door...
Page 35: ...PR_I017 2023 01 23 EN 35 ANNEX 2 Fans electric wiring diagram...