16
November 5, 2015
Chimney connector installation
The chimney connector is a set of single or double wall flue pipes
and elbow installed between the stove collar and the chimney
collar. Components of single wall chimney connector are
available at any hardware store and there is no precise standard
or regulation. However, some rules must be followed to install
solid fuel burning equipment.
Double wall chimney connector
Your J.A. Roby
ROBY2500/
ROBY2500 CUISINIERE cook
stove was approved for the use of a single wall chimney
connector with heat shield, but it is possible to install a 6
inch (15.2 cm) double wall certified chimney connector. In
this case, you must detach the pre-cut pieces of the top, the
bottom and each side of warming oven, in order to make
holes for double wall chimney connector.
•
We recommend to detach the removable pieces
before assembling the cook stove warmer.
ATTENTION:
•
For the clearance between combustible materials
and double wall chimney connector, see
manufacturer manual.
Single wall chimney connector
For the single wall chimney connector, you must use the
connector of 6 inch diameter with a minimum thickness of
24 gauge (0.025 inches 0.64 mm). For the section coming
out of the warming oven, install a metal heat shield,
covering the straight and curving sections with 1 inch (25.4
mm) thick.
ATTENTION:
•
If you don’t have heat shield, you must keep the
cook stove away in order to maintain the distance
of 18 inches or more from combustible materials.
•
Any horizontal section must be sloping upwards
1/4 inches (6.35 mm) by feet (30 cm) toward the
chimney collar. This section should not exceed
36 inches (91,4 cm).
•
The clearance between the roof and the single wall
chimney connector must be 18 inches (45.7 cm) or
more.
•
Regarding the clearance between the roof and the
double wall chimney connector, follow the
manufacturer indication
Assembly of connecting parts
1.
Make a brief installation of all sections and elbows (if
necessary) to ensure that you respect the clearances and
inclinations of the horizontal sections. You must also verify
if you have all the necessary parts for final installation.
o
For direct vertical installation, you will need:
1 x vertical section of 24 inches (61 cm) or more
1 x adequate length of telescopic chimney part
allowing you to connect the last chimney
connector section to the chimney collar.
Note: For higher roof, more parts might be needed.
o
For horizontal installation, you will need
1 x vertical section of 24 inches (61 cm) or more
1 x 90° elbow
1 x adequate length of telescopic chimney part
Note: For better performance, two 45 degree elbows with
or without straight section in between are preferable.
2. Disassemble the whole thing and start screwing the pieces
from the stove to the roof chimney collar.
Couper le contour
Cut the edge
Couper le contour
Cut the edge
Couper le contour
Cut the edge