11
Side firebricks installation
1) Put 3 bricks «A» and 1 angled brick «T» beside the right
air passage.
2) Put one brick «T» on the one installed at Step 1, then place
1 brick « C » beside it as shown in the illustration. Fix the
Retainer with 2 screws
3) Repeat steps1 2 and 3 to do the other side of the stove.
Firebricks installation on the pipes
The firebricks must be put on the 5 pipes from the back of the
combustion chamber. These Bricks keep a maximum heat
inside the combustion chamber to help the air supply from the
pipes burn the entire gas coming out from wood.
The rockwool over the bricks can reduce a considerable
leakage between the bricks and also keep maximum heat
inside the combustion chamber. It should cover up all the
bricks and each top side of the air passage.
IMPORTANT:
The rockwool must not obstruct the smoke exit.
Verify from the hole of the chimney collar to make sure if it is
in the right position. Then, place 2 half round stainless plates
as shown in the picture.
1)
Put 4 « A » bricks over the 2 pipes at the rear and push
them against the back of the combustion chamber.
Summary of Contents for ULTIMATE TOR 2015