PR_I020/2023-08-11-EN
Revision: 5
12
2) Before to put the 4 bricks « A » over the 3 front pipes as
shown in the illustration, insert the rockwool on the 4 bricks
previously put on the tube. Be sure to eliminate any space
between the bricks previously placed at the rear.
3) The rockwool is over the bricks and be sure then the
smoke exit way is not obstructed.
4) Put two half metal discs over the rockwool near the rear
deflector already in place. Be sure to put it under the rear
deflector to maximise the clearance between rockwool and
the rear deflector. You can look from the hole of the chimney
collar to be sure the rockwool is not obstructing the space.
WARNING: Obstructing smoke exit way under
deflector can force smoke to exit by the door and
the stove must not work properly.