background image

PR_I020/2023-08-11-EN

                                                   Revision: 5 

   

                      

19 

Vertical Installation

 

The wood burning appliance must be installed in accordance 
with  the  applicable  local  laws  or  the  CAN/CSA-B365.  Follow 
the chimney manufacturer’s instructions to install the chimney. 

Always pass chimney between joists. If you have to cut a joist, 
refer to the National Building code to know how to do it safely 
to avoid structural integrity fail. Otherwise, call a carpenter or a 
certified installer.  

Always  frame  around  chimney.  Keep  minimal  clearances 
indicated in your chimney manual. 

Do  not  fill  the  gap  between  the  framing  and  the  chimney. 
Nothing must be in contact with the chimney. 

Always install a fire-wall at each level, in a wall, a ceiling, a floor 
and an attic. 

A special fire stop needs to be installed into the attic. It keeps 
insulation distant from the chimney. 

Always pass with a straight section through joists. 

The chimney should be supported by the cathedral roof. Install 
a frame for this purpose around the opening.  

Weight of the chimney must not be supported by the stove. 

 

 

Summary of Contents for ULTIMATE TOR 2015

Page 1: ...LOCAL AUTORITY ABOUT RESTRICTION AND INSTALLATION INSPECTION IN YOUR AREA Instruction Manual 490 rue de l Argon Qu bec CANADA G2N 2C9 T l 418 849 8095 Fax 418 849 0077 www jaroby com Certified and tes...

Page 2: ...stion air source 20 Air Inlet Obstruction 20 Part replacement 21 Steel deflector replacement 21 Front deflector replacement 21 Stainless steel tubes replacement 21 Stainless steel tube Installation 21...

Page 3: ...th 24 inches Fuel Orientation front to rear Fuel Seasoned cord wood A range of BTU outputs based CSA B415 1 Default Efficiency and the burn rates from the low and high CSA B415 1 emission tests using...

Page 4: ...PR_I020 2023 08 11 EN Revision 5 4 Rating plate...

Page 5: ...PR_I020 2023 08 11 EN Revision 5 5 Appliance Dimension...

Page 6: ...Door Opening 16 in x 9 5 in 40 6 cm x 25 4 cm Interior Height 14 1 2 in 36 8 cm Interior Width 19 3 4 in 50 1 cm Interior Depth 15 1 2 in 38 cm Recommended log length 20 in 50 8 cm Chamber combustion...

Page 7: ...follows a In the event of a chimney fire b Evacuate the house immediately c Notify fire department The average of the CO emission carbon monoxide is 68 5 g hr To maintain this rate it s recommended t...

Page 8: ...s at the back for a smoke simple pipe with a heat shield and 20 inches of lateral MINIMUM clearance In case of a single pipe without heat shield you must keep your single smoke pipe 18 inches away fro...

Page 9: ...ove on its back carefully not to damage the paint 4 Loosen the nut 2 without removing it completely 5 Install the legs 1 as illustrated below Attention Make sure the legs are in place correctly positi...

Page 10: ...t 2 brick A and 1 H 4 Insert brick A on the right and R on the left to finish the installation at the bottom Back firebricks installation 5 Put 4 bricks A and C against the back wall 6 Put the 3 brick...

Page 11: ...ricks keep a maximum heat inside the combustion chamber to help the air supply from the pipes burn the entire gas coming out from wood The rockwool over the bricks can reduce a considerable leakage be...

Page 12: ...the bricks and be sure then the smoke exit way is not obstructed 4 Put two half metal discs over the rockwool near the rear deflector already in place Be sure to put it under the rear deflector to max...

Page 13: ...PR_I020 2023 08 11 EN Revision 5 13 Firebox configuration and part list...

Page 14: ...tallation of this appliance by a certified installer Note This appliance has to be connected to 6 inches 15 24 cm factory build chimney HT UL 103 or CAN ULC S629 compliant or a 6 inches 15 24 cm mason...

Page 15: ...rer indication ALL SECTION AND ELBOW MUST BE CLEAN AND IN GOOD CONDITION AND MUST BE APPROVED FOR WOOD BURNING 1 Chimney connector assembly installation Make a summary installation of all sections and...

Page 16: ...e sealant to make the building airtight Note This is a general chimney installation method Be sure to refer to the manufacturer s manual for more details of installation of your chimney 1 Determine th...

Page 17: ...method has to be safe to prevent fire Refer to your local authority to get the latest information To install the stove in an abandoned masonry the chimney must have a certified metallic sleeve cover...

Page 18: ...installed in accordance with the applicable local laws or the CAN CSA B365 Follow the chimney manufacturer s instructions to install the chimney Always pass chimney between joists If you have to cut a...

Page 19: ...arpenter or a certified installer Always frame around chimney Keep minimal clearances indicated in your chimney manual Do not fill the gap between the framing and the chimney Nothing must be in contac...

Page 20: ...e recommend you to open slightly a window of the room where the stove is situated in order to avoid a negative air pressure when an appliance mentioned above is working WARNING DO NOT INSTALL THIS APP...

Page 21: ...flector and take it out 2 Install the new deflector and screw it in place Pay attention to put all screw 3 Install previously disassembled tubes rockwool and half round steel plates Follow the instruc...

Page 22: ...PR_I020 2023 08 11 EN Revision 5 22 Tube support installation Put the support over the tube and fix it at the top of the combustion chamber with the screws as shown...

Page 23: ...tning fire After installing correctly the stove following the installation instruction of the manufacturer you are ready to light it 1 Turn the admission handle in horizontal position to set the prima...

Page 24: ...process wood might shrink split twist or change shape In general wood must be dried before use Air drying i e seasoning is the most common method used for cordwood Season wood outdoors through the sum...

Page 25: ...ey flue of a slow burning fire As a result creosote residue accumulates on the flue lining Creosote can take several forms such as tarry liquid black soot or crystals When it catches fire this creosot...

Page 26: ...recommends using products for this purpose or an oven cleaner only for glass part Avoid cleaning hot glass and cleaning with abrasive Cleaning hot glass can cause a thermal shock and break the glass D...

Page 27: ...ithout giving any tension Verify the length of rope 5 Cut it inches over the require length and repeat step 1 and 2 Glass fiber rope installation 1 Put a high temperature sealant in the clean groove t...

Page 28: ...PR_I020 2023 08 11 EN Revision 5 28 Annex 1 Door assembly Square Door Arc Door...

Page 29: ...PR_I020 2023 08 11 EN Revision 5 29 Annex 2 Circuit diagram of fan Snap Disc Box parts description...

Page 30: ...can be replaced Bricks Stove ceramic glass Arc Stove ceramic glass Rectangular Spring Handle Stove Door with handle Fans Flat fiberglass rope around glass Round fiberglass rope Slotted Brick Washer T...

Page 31: ...nd through the access opening Take care of putting the bolt s screwing part oriented downward Fastened the fan to the stove with the 4 lock washers D and the 4 nuts E provided with the fan kit as show...

Page 32: ...location in the adjacent picture Put them inside the fan housing by passing the hand through the access opening Put the second blower in the opposite orientation compared to the first blower Screw the...

Page 33: ...t after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser...