3/3
5. Protection codes and warnings
E16
Block protection
If the desk displays "E16" an alarm will sound when either the desktop is vibrating,
has collided with an object or has tilted. To stop the alarm, raise the desk up or
press any key to clear the alarm whilst the desk is raising up.
To prevent the desk from enabling the alarm, ensure the desk is does not vibrate,
collide with an object or tilt during operation. If the alarm sounds again follow the
above.
HOT
Overheat protection
The desk has entered the overheat protection after operating for a long time. Wait
for 18 minutes before operating again to allow the desk to cool down.
E10
Motor fault protection
Check and confirm the connection between motor and controller is correct as per
the Assembly Instructions, then power the desk off and on again and follow the
follow the Stroke Reset Process.
E20
Overload protection
The desk has more weight than the intended weight capacity. Remove objects from
the desktop to ensure the desk is not overload with weight then power the desk off
and on again or follow the Stroke Reset Process.
E31
Undervoltage protection
An alarm will sound when the supply voltage is lower than the required voltage.
Power the desk off and on again or follow the Stroke Reset Process.
E32
Overvoltage protection
An alarm will sound when the supply voltage is higher than the required voltage.
Power the desk off and on again or follow the Stroke Reset Process.
E60
Out-of-step protection
Check and ensure the motors of each leg are at an identical height and their
connection to the controller is correct as per the Assembly Instructions, then power
the desk off and on again or follow the Stroke Reset Process.