SPECIFICATIONS:

 

 

Unit specifications: 
Voltage:                   

120VAC @ 60Hz 

Amperage:               

(1) 10 amp service for air/water or air only.  
 

Weight:                    

230 lbs with pallet attached 

Height:   42 

3/4" 

Width:  

 

 

18" 

Depth:   20" 
 

 

 
________________________________________________________ 

 
Air specifications: 

Compressor:  

     

Thomas 120VAC @ 60hz, ¾ HP twin head 

Gast 120VAC @ 60HZ, ¾ HP- twin head 
(Gast is the standard for this unit) 

 

Timer:  

 

  

SSAC- 120VAC @ 60HZ 

 

 
_________________________________________________________________ 

 
Water specifications: 

Solenoid: 

 

  120VAC 

60HZ 

(15000 UNIT ONLY) 

 
 

_________________________________________________________________ 
 

NOTE: “UNIT INTENDED FOR COMMERCIAL USE ONLY” 

 
Duty 

cycle: 

  4 

minutes run time- max 

 

 

 

 

4 minutes off time  

 

 

 

 
 
 

 

Summary of Contents for 15000

Page 1: ... Table of contents Page 2 Product Information Page 3 Specifications Page 4 Important Safety Instructions Page 4 5 Installation Page 5 Operation Page 6 Maintenance Page 6 Troubleshooting Page 7 9 Part Drawings Page 10 11 Wire Diagrams ...

Page 2: ...ber can be found on the tag that comes attached to the keys There may be more than one key number depending on unit Please keep this information with your records MODEL _________________________________________ SERIAL _________________________________________ KEY NUMBER S _________________________________ DATE PURCHASED _______________________________ DISTRIBUTOR __________________________________...

Page 3: ...Air specifications Compressor Thomas 120VAC 60hz HP twin head Gast 120VAC 60HZ HP twin head Gast is the standard for this unit Timer SSAC 120VAC 60HZ _________________________________________________________________ Water specifications Solenoid 120VAC 60HZ 15000 UNIT ONLY _________________________________________________________________ NOTE UNIT INTENDED FOR COMMERCIAL USE ONLY Duty cycle 4 minu...

Page 4: ...AN CAUSE AN EXPLOSION WHEN LOCATED IN GASOLINE DISPENSING AND SERVICE STATIONS INSTALL AND USE AT LEAST 20 FEET 6 M HORIZONTALLY FROM THE EXTERIOR ENCLOSURE OF ANY DISPENSING PUMP AND AT LEAST 18 INCHES 450 MM ABOVE A DRIVEWAY OR GROUND LEVEL Unit to be supplied with 110VAC 10AMP service Make sure adequate wire service is supplied to unit under sizing wire may result in damage to compressor and or...

Page 5: ...used If air is selected attach chuck to valve stem a squeeze tire chuck handle to inflate Inflate tires only to manufactures specifications If water is selected squeeze handle to activate When finished slowly walk hose back to machine and allow hose to coil up on retractable reel ...

Page 6: ...RN OUT CHECK AIR HOSE FOR LEAKS AND AIR CHUCK ALSO CHECK FOR LEAKS AROUND COMPRESSOR CHECK AIR CHUCK TO MAKE SURE NO DEBRIS IS AIR PATH ALSO CHECK ORING AROUND AIR CHUCK IS IT BLOCKING THE AIR PATH IS IT UNLOADING ALL THE TIME SLEEVE IN COMPRESSOR MAY BE PITTED OR SCRATCHED UP PISTON ORING MAY BE WORN OR DAMAGED DEBRIS IN VALVE PLATE OPENING IS NOT ALLOWING IT TO SHUT REPAIR KIT MAY BE NEEDED WARN...

Page 7: ...7 ...

Page 8: ...8 ...

Page 9: ...9 ...

Page 10: ...10 ...

Page 11: ...11 ...

Reviews: