background image

REV 6-11-2019 

IMPORTANT SAFETY INSTRUCTIONS 

 

When using an electrical appliance, basic precautions should always be followed, including the following: 

 

READ ALL INSTRUCTIONS BEFORE USING (THIS APPLIANCE) 

 

WARNING 

– To reduce the risk of fire, electric shock, or injury:

 

Do not use on wet surfaces. 

Use only as described in manual. Use only manufactures recommended attachments. 

Do not allow to be used as a toy. Close attention is necessary when used by or near children. 

Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair and anything that 
may reduce air flow. 

Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts. 

Do not use to pick up flammable or combustible liquids, such as gasoline, or use in areas where they may be present. 

Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes. 

Do not use without dust bag and/or filters in place.

 

 

SAVE THESE INSTRUCTIONS 

 

Installation Instructions:

 

Determine location to mount unit (

“DANGER”  “THIS EQUIPMENT INCORPORATES PARTS SUCH AS SWITCHES, 

MOTORS, OR THE LIKE THAT TEND TO PRODUCE ARCS OR SPARKS THAT CAN CAUSE AN EXPLOSION. WHEN 
LOCATED IN GASOLINE-DISPENSING AND SERVICE STATIONS INSTALL AND USE AT LEAST 20 FEET (6 M) 
HORIZONTALLY FROM THE EXTERIOR ENCLOSURE OF ANY DISPENSING PUMP AND AT LEAST 18 INCHES (450 

MM) ABOVE A DRIVEWAY OR GROUND LEVEL.”

 

Run electrical service to that location 

(NOTE UNIT HAS WIRE PROVIDED UNDERNEATH TO CONNECT INCOMING 

POWER SUPPLY)

 

Grounding Instructions

: This appliance must be connected to a grounded metal, permanent wiring system; or an 

equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal 
or lead on the appliance. 

Circuit must be protected by GFCI device. 

All local and national electric codes must be followed for installation and use. 

Licensed electricians are recommended for installation. 
 

Summary of Contents for 9217

Page 1: ...Post Mount Vacuums Page 2 Product Information Page 3 4 Product Dimensions Page 5 Specifications Page 6 Important Safety Instructions Page 6 8 Installation Page 9 10 Programming Page 10 Operating Page 10 Maintenance Page 11 Troubleshooting Page 12 19 Parts List Page 20 21 Wiring Diagram ...

Page 2: ... the lower exterior of the can Key number can be found on the tag that comes attached to the keys There may be more than one key number depending on unit Please keep this information with your records MODEL ____________________________ SERIAL ____________________________ KEY NUMBER S _____________________ DATE PURCHASED ___________________ DISTRIBUTOR _______________________ J E Adams Industries 1...

Page 3: ...REV 6 11 2019 3 PRODUCT DIMENSIONS 9217 VAC ...

Page 4: ...REV 6 11 2019 4 PRODUCT DIMENSIONS 9218 VAC ...

Page 5: ...________________________________________________________________ Unit specifications 3 MOTOR VACUUMS 220V Voltage 220v 50hz Amperage 1 20 amp service is required for 3 motor units Weight 140 lbs with pallet attached Vac specifications Motors 3 220vac vacuum motors Fuses 3 8 amp inline fuses Stainless steel or lighted dome options Push button or coin operated start Single hose or dual hose inlets D...

Page 6: ...rettes matches or hot ashes Do not use without dust bag and or filters in place SAVE THESE INSTRUCTIONS Installation Instructions Determine location to mount unit DANGER THIS EQUIPMENT INCORPORATES PARTS SUCH AS SWITCHES MOTORS OR THE LIKE THAT TEND TO PRODUCE ARCS OR SPARKS THAT CAN CAUSE AN EXPLOSION WHEN LOCATED IN GASOLINE DISPENSING AND SERVICE STATIONS INSTALL AND USE AT LEAST 20 FEET 6 M HO...

Page 7: ...p not provided Vacuum is heavy Use assistance Vacuum hose installation 1 Cut vacuum hoses to desired lengths not too tight not excess slack leave a gradual bend 2 Thread ends into vacuum can counterclockwise 3 Thread hose into grey couplers and attach to arch using hose clamp 35000 11A post pictured ...

Page 8: ...REV 6 11 2019 8 Remove cover and make conduit connection at hole provided seal tite type fitting not provided Tie into factory electrical at this location ...

Page 9: ...nation of coins from 1 15 quarters A typical vend time would be 4 minutes 240 seconds which requires dip switches 3 2 and 8 to be set to on Again since this a non accumulating timer there is no calculation for time per coin Time in minutes dip switch settings 0 2 12 seconds 0 4 24 seconds 0 8 48 seconds 1 6 96 seconds 3 2 192 seconds 6 4 384 seconds Total time non accumulating Coins to start Timer...

Page 10: ...ber pad to eliminate leaks in vacuum system This will allow the opposite hose to have more suction while in use Maintenance All servicing of machine should be conducted by an authorized service representative Filter bags should be accessed and shaken down weekly It is recommended to keep a new set of bags on hand To maintain performance empty dirt bin from the canister on a regular basis This is v...

Page 11: ...n and install proper wire size for electrical service versus length or run Motor brushes may be bad or too short Replace motor brushes Vac hose clogged Clean debris from vac hose Filter bags need cleaned or dirt chamber needs emptied Shake or clean filter bags or replace and empty lower dirt chamber Vac hose is split Replace repair vac hose Cleanout door gaskets torn or worn Replace gaskets Vac mo...

Page 12: ...REV 6 11 2019 12 ...

Page 13: ...REV 6 11 2019 13 ...

Page 14: ...REV 6 11 2019 14 ...

Page 15: ...REV 6 11 2019 15 ...

Page 16: ...REV 6 11 2019 16 ...

Page 17: ...REV 6 11 2019 17 ...

Page 18: ...REV 6 11 2019 18 ...

Page 19: ...REV 6 11 2019 19 ...

Page 20: ...REV 6 11 2019 20 ...

Page 21: ...REV 6 11 2019 21 ...

Reviews: