Approved Installation Manual for the Experimental
Report No 104
EDM-350
Page 21 of 46 Rev A
Engine Data Management System Date 7-10-2021
Getting Started…Collecting Fuel Level Calibration Data using the
EDM as a meter
.
1. With power off, hold in
Button 4 (Button 1 being far left)
and then turn on power. For each EDM monitored
tank, create a
paper table
with the 5 calibration points and at what volume each will be. The zero-gallon
point reading is always taken with unusable fuel in the tank. Example of a completed table for
LEFT
tank:
LEFT
F
39.0 GAL
1907
¾
29.3 GAL
1431
½
19.5 GAL
1145
¼
9.8 GAL
971
E
0.0 GAL
685
2. This screen shown below provides real-time readings of all active fuel level sensors. Verify readings look
normal. Reading are arbitrary whole numbers
3. Now add fuel as needed to match the required volume for a particular point. Cycle power between readings
(hold in button 4), then take a reading and record it on paper adjacent to that point.
4. Repeat this process until all points have been recorded for each tank.
With AUX it would
say LAUX and
RAUX
Actual Screen Shot