Page 30
Engine Data Management
Section 6 - Fuel Flow Option Operation
Fuel Flow Display Select Switch
The select switch is a three-position toggle switch mounted on your
instrument panel near the display of the EDM. It affects only the display
scan.
•
In the
EGT
(
T
emperature)
position only the installed
temperature (and battery voltage) parameters are displayed.
•
In the
ALL
(
A
ll
) position, the EDM both installed
temperature and fuel flow parameters are displayed.
•
In the
FF
(
F
uel Flow)
position only fuel flow parameters are
displayed.
Any alarm warning will appear regardless of the select switch setting.
These parameters are displayed in the digital display in either the
Automatic or Manual modes or during the pilot programming procedure.
The select switch does not effect the analog display.
Start Up Fuel
After initial self-test, you will be asked to inform the EDM of start up
fuel. The EDM will display
FUEL
for one second, and then flash
FILL?
N
until any button is pressed. If your aircraft has tank fill tabs and no
auxiliary tanks, you can use the auxiliary tank feature to select either
filling to the tank tabs or topping the tank. See “Main Tank Capacity”
and “Auxiliary Tanks” beginning on page 47 to program the EDM for
this feature. The EDM does not differentiate fuel flow between the main
and auxiliary tanks; it considers only
total
fuel in the aircraft.
During
flight you may also inform the EDM of startup fuel using the pilot
program mode display if you forgot to do so at start up.