For Your Safe Flight
Page 41
F, A
KF-SET
29.00
=
K
F
KF-set, hold both STEP and LF buttons
simultaneously for five seconds to begin
the next sequence.
29.00
=
K
F
2
9.00
One digit will be flash and the LF
button will adjust up or down. STEP to next
digit
.
Hold both buttons to exit set mode.
F, A
ACCUM?N ACCUM?N
⇔
ACCUM?Y
N—No—Upon informing the EDM that you
refueled the aircraft, reset total fuel used to
0.
Y—Yes—accumulate total fuel used rather
than reset to 0 at each refueling.
F, A
GPS - C
=
2
0 … 6
GPS COM FORMAT.
T, F,
A
DUMP?
N
N
⇒
NEW
⇒
ALL
⇒
Memory dump. Select to transfer ALL or
only NEW data. The
END Y
step is
skipped after a successful a Long Term
Memory DUMP.
T, F,
A
END Y
END Y
⇔
END N
Y—Yes to exit; N—No to review list again.
Section 9 - Programming the EDM-800 Horsepower Constant
You must adjust the HP Constant once for your aircraft. The
Fuel Flow
Option is required to be installed to display percent of horsepower.
The default display will be RPM if Fuel Flow is not operational. You
must perform this adjustment in the air while the aircraft is in flight.
1.
Enter the pilot program mode by simultaneously holding the
STEP
and
LF
buttons for five seconds.
2.
Tap
STEP
repeatedly until you see
HP-? Y
. If you see
HP-?
N
, change the N to a Y
by tapping the
LF
button, then hold both the
STEP
and
LF
buttons display until you see
HPC
=
I25
.
3.
Referring to the Aircraft Flight Manual (AFM) set the engine to a
constant power setting of 65 to 70% at 25° to 50° Rich of peak and
maintain straight and level flight at any altitude below 10,000 feet.
View the reading in the %HP display and see how close it is to your
current engine percent HP. If the value in the display not at your
current engine percent HP setting, then change the HP reading by