Page 52
Engine Data Management
Low Time Alarm Limit
Select the value of the time remaining, in minutes, that triggers the alarm.
Time remaining is calculated at the current fuel flow rate.
Low Fuel Alarm Limit
Select the value of the fuel remaining, in the selected fuel flow units, that
triggers the alarm. Fuel remaining is calculated at the current fuel flow
rate.
Carburetor?
Different response filters are used depending on whether your engine is
carbureted or fuel injected. The filter for a carbureted engine has a
slower response time to reduce sudden fluctuations in readings.
Number of Cylinders
This applies only to EDM-800. Set
CYL
=
4
or
6
depending on your
engine. Exceptions:
•
4 cylinder engine with dual (all-in-one) magnetos set to
CYL
=
8
.
•
4 cylinder Laser ignition set to
CYL
=
8.
•
6 cylinder Laser ignition set to
CYL
=
I2
.
Section 15 - Real-Time Serial Data Port
Serial Data Output Port Configuration
The real-time serial port is active only if the alarm limit parameter
RECRD
is set to
RECRD? N
.
The RS-232 port on your computer should be configured as follows:
9600 baud, 1 stop bit, 8 data bits, no parity. The connector is 2.5 mm ID,
5.5 mm OD.
Do not connect a power source to the serial output port
connector.
Real-time Serial Data Output Format
Every six seconds a data block is transmitted, formatted as comma
delimited ASCII text. Every 60 lines a header line is transmitted. Note:
the format for the
recorded data
when using the Long Term Data
Memory is compressed binary and not compatible with the text format
shown here.