Every time you fine tune the K factors, record the
measurements here:
Right Engine
Date
EDM-
760 fuel
used
actual
fuel used
Current K
factor
Left
Right
New K factor
=
x
/
Left
Right
Fuel Flow Option Programming Procedure
Setting the K factor
This procedure is different than for setting other parameters. Place the
select switch in the
FF
position. If you haven’t already done so, start the
pilot programming procedure, simultaneously hold the
STEP
and
LF
buttons for five seconds. You will see the word
PROGRAM
for two
seconds.
1. Tap STEP button to advance to the screen 29.00=KF
LFT.
2. Hold both the STEP and LF buttons simultaneously for five
seconds. First digit blinks:
2
9.00.
3. Tap or Hold the LF button to change flashing digit:
I
9.00
4. Tap STEP button for next digit: I
9
.00.
5. Tap or Hold the LF button to change flashing digit: I
8
.00.
6. Tap STEP button for next digit: I8.
0
0.
7. Repeat items 5 and 6 for the remaining two digits.
8. Hold STEP and LF buttons simultaneously for five seconds to store
the left engine K-factor.
9. KF= 29.00 is now shown.
RT
10. Repeat steps 2 through 8 to adjust the right engine K-factor
.
For Your Safe Flight
Page 45
Summary of Contents for EDM-760 TWIN
Page 69: ...For Your Safe Flight Page 63 ...