For Your Safe Flight
Page | 13
2
nd
Button
In Automatic or Manual modes, tapping the
LF
button will activate the
Lean Find mode.
In the LF mode holding the
LF
button after peak EGT is found will
display the peak EGT.
In Automatic or Manual modes holding the
LF
button for three
seconds will toggle between Standard and Normalize (NRM) views.
In the programming mode, tapping the
PLUS
or
MINUS
button will
allow you to edit a parameter value.
Holding
LF
during power up will display the primary alarm limits after
the self-test is complete.
1
st
and 2
nd
Buttons
Holding both the
STEP
and
LF
buttons simultaneously for five
seconds will enter the pilot programming mode.
Just after entering Lean Find Mode (but before any EGT has risen),
holding both First and Second buttons for five seconds will toggle
between LOP or ROP leaning modes.
Tapping both the
STEP
and
LF
buttons simultaneously in Manual
mode toggles to ‘include’ or ‘exclude’ the displayed non-primary
measurement from the Automatic mode. Note: Measurements are
never excluded from the Manual mode.
3
rd
Button
Tapping
DIM
(brightness decreases) or holding
DIM
(brightness
increases) allows decrease or increase brightness respectively. Hold
on start-up to enter fuel level table
2
nd
and 3
rd
Buttons
Holding both the
LF
and
DIM
buttons simultaneously will display the
Hobbs readings. Tap button labeled
NEXT
to see additional
information screens.
4
th
Button (ALL/EGT/FF)
Select what is shown during Scanner auto-sequence. Choices are
ALL
,
EGT
or
FF
. Highlighted one is what is active. Hold on start-up to
enter fuel level readings.