For Your Safe Flight
Page | 56
Capturing the sender reading at each calibration point:
Getting Started…Collecting Fuel Level Calibration Data
using the EDM as a meter.
1. With power off, hold in
Button 4 (Button 1 being far left)
and
then turn on power. For each EDM monitored tank, create a
paper table
with the 5 calibration points and at what volume
each will be. The zero gallon point reading is always taken with
unusable fuel in the tank. Example of a completed 5 point table
for
LEFT
tank:
LEFT
F
39.0 GAL
1907
¾
29.3 GAL
1431
½
19.5 GAL
1145
¼
9.8 GAL
971
E
0.0 GAL
685
2. This screen provides real-time readings of all active fuel level
sensors. Verify readings look normal. Reading are arbitrary
whole numbers
3. Now add fuel as needed to match the required volume for a
particular point. Allow this to settle, then take a reading and
record it on paper adjacent to that point.
4. Repeat this process until all 5 points have been recorded for
each tank.