PAGE 25
SCENECONTROL 500 OPERATING INSTRUCTIONS
Design, Manufacture and Installation of Theatrical Equipment Worldwide
(315) 451-3440
Fax (315) 451-1766
www.jrclancy.com
Rev 1: February 15, 2007
cue loading when the preceding one is complete. At the completion of cue Manual C3, the label on the violet
icon will update to Manual P1 if cue Manual C3 was set for Auto Load. The status displays will show
information for the sets that are in motion as each move is executed, as shown previously.
CHANGE SHOW
The Edit Level password allows the
operator to change the show that is
active. A show includes a group of
sets, the soft upper and lower limits
for those sets, the Presets and Cues
that have been defined for the show.
The first step in changing shows is to
open the System Config tool, using
the SYSTEM CONFIG button at the
top of the screen. When this tool is
open, click the Change Show button
to open the change show file access
screen.
Touch a show in the main pane to
highlight it. Once a show is
highlighted, touching the DELETE
button at the right of the screen will delete the highlighted show. Touching the RENAME button will open an
alphanumeric keyboard so that the new name of the show can be typed in. Touching the COPY button will
make a copy of the selected show, and open an alphanumeric keyboard so that the new name of the copy
can be typed in. Touching the Select button will load the highlighted show.
Touching a folder icon in the main pane will select that folder, and bring up to new buttons at the right of the
screen. The NEW SHOW button will create a new show in that folder, and will pop up an alphanumeric
keypad so that the new name of the show can be typed in. The NEW FOLDER button will create a new
folder, and will pop up an alphanumeric keypad so that the new name of the folder can be typed in.
By highlighting the show "First Show" and touching the Select button at the upper right of the screen, we can
load this show.
The preset page displays the sets that
are part of this show. By touching the
Show icon in the upper middle pane to
highlight it, each set's soft limits are
displayed in the lower middle pane. SLL
refers to the Soft Lower Limit, and SUL
refers to the Soft Upper Limit. A soft limit
can be redefined by touching (or double-
clicking) the limit you want to change. A
position keypad will pop up, and the
operator can key in a new limit value.
When the "Done" key is pressed, the
keypad will disappear and the new value will appear in the limits list.