630 System Manual
Version 1.1 December 14, 2010
54
J2 630/615/580 UPS
Specifications
Hardware
To install and use the J2 UPS module:
1: Remove the power supply adaptor from the base of the unit.
2: Install the UPS module where the power supply was mounted.
3: Connect the power output jack of the UPS to the power in jack of the unit.
4: Connect the Serial cable of the UPS to the serial port you wish to use. *
5: Connect the power supply adaptor to the UPS power in jack.
6: Connect the power supply adaptor to the mains power. **
7: Configure the Windows UPS drive as shown.
* The serial port connection is not needed for Windows CE.
** When first installed the mains power should be applied for 5 hours to fully charge the
batteries. The unit may be running during this time but will take longer to charge.
Batteries Run Time
2 hours for the standard J2 630, run time will vary
depending on the application loading
Power In
19 Volts DC
Power Out
13-16.8 Volts DC, 8 amps maximum
Data Interface
RS232 cable, RJ45 connector
Batteries Type
2 – 4 18630 cell Li-Ion pack with protection circuit
Battery Life
500 full discharge cycles
Charge Time
5 hours from full discharge
Charger Type
Smart Microcontroller based
Software
XP Standard Generic UPS driver
Size
6” x 3.1” x 1.7” (152mm x 79mm x 43mm)