5.4 50 Hours Check
Details of specific operations are shown in Chapter 6 "Maintenance".
* Conduct the items shown under 25 Hour Check at para. 5.3.
5.5 100 Hours Check
Details of specific operations are shown in Chapter 6 "Maintenance".
* Conduct the items shown under 25 Hour Check at para. 5.3.
* Renew spark plugs, if necessary.
5.6 TBO
Details of specific operations are shown in Chapter 6 "Maintenance".
* Engine Overhaul, in accordance with Service Bulletins
* Conduct the items shown under 25 Hour Check at para. 5.3.
* Check clearance on throttle valve shaft. If radial clearance exceeds 0.5mm (0.020"),
repair carburettor.
The overhaul work must be carried out to Jabiru specifications at an approved
aeronautical service facility or by an approved Jabiru Service Centre.
If necessary, changes to the TBO Limit due to operational experience, will be announced
by Jabiru in a Service Bulletin.