Page No: 26
Issue No: 1
Date: 031100
Issued By: PJA
6.0 MAINTENANCE
6.1 Lubrication System
Oil Change, Oil Filter Change, Visual Check for Leaks.
* Drain the oil while engine is still warm.
* Change the oil filter at 100 hour inspection.
* Fill with oil. Capacity is 3.5 litres (3.69 US Quarts)
* Check oil level. The MAX mark must not be exceeded.
* Use only registered brand oils meeting the specification detailed in Para. 2.5.
6.2 Air Intake Filter
Clean filter by removing from the intake housing & blowing compressed air against the
direction of the intake flow.
For operation in heavy dusty conditions, clean air filter at shorter intervals than
recommended for normal conditions.
A clogged filter will reduce engine performance as well as promote premature engine
wear.
6.3 Carburettor Adjustment
Open idle mixture screw approximately 1-1/4 turns, fine adjust for a smooth idle. The
determination of the main jet is carried out on a dyno at 107 ft above Mean Sea Level.
IMPORTANT
Check & oil carburettor joints & linkage
6.4 Compression Check
Measure compression using a compression tracer. Readings are taken with fully open
throttle valve at engine oil temperature between 30 & 70 degrees C (90 to 160 degrees F).
Summary of Contents for 3300
Page 4: ...Page No 4 Issue No 1 Date 031100 Issued By PJA List of Amendments Page Amendment Date Issue...
Page 8: ...Page No 8 Issue No 1 Date 031100 Issued By PJA 1 1 Denomination of Cylinders...
Page 11: ...Page No 11 Issue No 1 Date 031100 Issued By PJA 3 0 PERFORMANCE GRAPHS...
Page 48: ...Page No 48 Issue No 1 Date 031100 Issued By PJA...
Page 52: ...Page No 52 Issue No 1 Date 031100 Issued By PJA...
Page 67: ...Page No 67 Issue No 1 Date 031100 Issued By PJA Drawing 9430064...
Page 89: ...Page No 89 Issue No 2 Date 031100 Issued By PJA...