JABLOTRON FUTURA
SYSTEM DESIGN GUIDE
Page 3/16
JABLOTRON LIVING TECHNOLOGY
1
1 .. 2
2 .
. Tech n ica l p a ra m et ers
Tech n ica l p a ra m et ers
The Futura heat recovery unit comes in two power output variants.
D es crip t ion
D es crip t ion
M
M
L
L
Air flow
50-250 m
3
(1770-8830 cubic feet)/h
100-350 m
3
(3530-12360 cubic feet)/h
Model identification brand
Futura M
Futura L
Specific energy consumption (SEC) in
kWh/(m
2
.a) for each applicable
climate zone and each applicable
SEC class
A+
A+
Dimensions (height x width x depth)
835 x 995 x 522mm (32.9" x 39.2" x 20.6")
835 x 995 x 522mm (32.9" x 39.2" x 20.6")
Weight
47 kg (104 lbs)
47,5 kg (105 lbs)
Declared typology
bidirectional
bidirectional
Drive type
variable speed drive
variable speed drive
Heat recovery system type
recuperative
recuperative
Heat recovery efficiency
91,8 %*
91,4 %*
Acoustic power level Lwa
46 dBa**
46 dBa**
Reference flow
175 m
3
/h*** (6180 cubic feet per hour)
245 m
3
/h*** (8652 cubic feet per hour)
Reference pressure difference
50 Pa***
50 Pa***
SPI
0,34 W(m
3
/h)***
0,33 W(m
3
/h)***
Electric power input of the fan
including motor control equipment at
max. flow and max. pressure
230 W
320 W
Power input of electric afer-heating
0 -350 W, continuously regulated
0 -350 W, continuously regulated
Maximum input incl. electrical after-
heating
580 W
670 W
Condensate
condensate drain, HT pipe 32mm (1.26"),
siphon
condensate drain, HT pipe 32mm (1.26"),
siphon
Electric connection
230 V/50 Hz, 16 A; connection to electric
mains via power socket
230 V/50 Hz, 16 A; connection to electric
mains via power socket
Operational range without
preheating
-19 °C do +45 °C (-2.2 °F - 113 °F)
-19 °C do +45 °C (-2.2 °F - 113 °F)
Fans
2× EBM Papst with integrated electronics
and air flow regulation
2× EBM Papst with integrated electronics
and air flow regulation