background image

GD-06 ALLEGRO GSM dealer 

2/2 

MHG51302 

3.3. Customization of SMS texts and access 

codes 

The default texts of reporting SMS and incoming SMS 
instruction can be modified using the following programming 
SMS: 

MASTER TXT index, text  

 
index

   index number according to the following 

table 

text

  

new text, which will be used in SMS 

messages 

Basic SMS reports’ texts 

Index 

Default 

Description 

10 

P1 

Description of P1 input terminal   

11 

On 

P1 input terminal is triggered 

20 

P2 

Description of P2 input terminal   

21 

On 

P2 input terminal is triggered 

30 

P3 

Description of P3 input terminal   

31 

On 

P3 input terminal is triggered 

40 

P4 

Description of P4 input terminal   

41 

On 

P4 input terminal is triggered 

 

Basic SMS instructions’ texts 

Index 

Default 

Description 

50 

P5 

Description of P5 output terminal 

60 

P6 

Description of P6 output terminal 

70 

RELAY 

Description of the relay output 

100 

ON 

Instruction to switch on an output  

101 

OFF 

Instruction to switch off an output 

109 

USER 

User access code  

110 

MASTER 

Master access code  

 

You can send multiple texts separated by commas and blank 
spaces in one programming SMS.  

 
Examples:  

a) 

“MASTER TXT 10, Security system, 11, armed” 

will 

customize the input P1 setting to indicate a security 
system’s status. If a corresponding alarm system 
output triggers the P1 when arming, then SMS 
report “Security system armed” is sent. 

b) 

“MASTER TXT 71, Heating” 

will modify the remote 

SMS instruction to switch on a heating system 
connected with the relay output to “Heating on”. 

c)  “MASTER TXT 110, Big elephant” 

will change the 

master access code to “Big elephant”

 

 

4. Operation 

After installation of the GD-06 

ALLEGRO

 and programming 

of the telephone numbers, the GD-06 is ready for operation.  

• 

Triggering of any input P1 to P4 will cause the sending 
of a SMS report to the telephones registered in the 
positions TEL1 to TEL6.  

• 

From a GSM phone, you can send an SMS instruction 
to switch on or off the P5 and P6 outputs.  

• 

You can also switch the relay on or off by making a 
phone call to the GD-06 from a phone registered to 
TEL1 or TEL2 memory positions. The GD-06 

ALLEGRO 

doesn’t answer this call, so you don’t pay any 
telecommunication fee for this remote control. 

 

Notes: 

1.  You can remotely control the GD-06 from any phone: 

not only from the ones stored in the memory TEL1-
TEL6. You just have to add the master (default 
MASTER) or user (default USER) access code in front 
of the instruction.  

Example: “MASTER ON P5” 

2.  The SMS instructions texts are case insensitive. It 

means that instruction 

“ON P5”

 is equal to 

“on p5”

.  

 

5. Advanced programming 

More detailed programming can be accomplished from 
Internet using the web page 

www.gsmlink.cz

. Follow the 

product registration instructions to get access to a secure 
web page. Use the registration code printed on the warranty 
certificate (the code has a form xxxx-xxxxx-xxxx and it is 
unique for each system). From the GSMLink, you can 
program your GD-06 ALLEGRO easily regardless of where 
in the world you are located. The best performance will be 
obtained if your SIM card enables GPRS data transmission. 
Form the GSMLink server you can: 
 

• 

Check the current status of all inputs and outputs 

• 

Control the outputs 

• 

Program the GD-06 

• 

Change the SMS tetxts (only when GPRS data 
connection is enabled) 

 
If you don’t have Internet access, you can also use SMS for 
the advanced programming. You can find all details in the 
Expert programming manual. 

 

 

 
 