Page 2: ...uired 12V from 1 2Ah to 40Ah stand by consumption 25mA back up power output 12V max 500mA inputs eight loops FIRE TAMPER and 6 fully programmable loops type of loops balanced with End Of Line resistor 10k remote control inputs digital bus for external keypads programmable optional pulse input outputs overswitching relay contact 1A at 60 V external siren output 0 5A at 12 V backup siren output BS f...

Page 3: ...nput is also triggered if normally closed contacts wired in series with EOL resistor are opened see the wiring diagram The Fire alarm is activated if a detector connected to a FIRE input is triggered The Tamper alarm can be triggered either by the built in tamper switch control panel keypads or by the tamper switches connected to the TAMP input The definition of zone 1 to 6 delay instant 24hr fire...

Page 4: ... 5 can be used connect all of them in parallel Check carefully that you have connected corresponding wires before you turn on the power to the control panel The built in keypad on the H 915C model is connected via INT KEY connector Control panel TAMPER There is a tamper switch to protect the housing of the control panel If you have only the H 915B main board don t forget to install the attached ta...

Page 5: ...on was enabled in the installer programming level If quick arming is enabled the H 915 can be AT HOME armed by entering only the 9 command DISARMING Enter a valid access code to disarm If the chime jumper in the H 915K keypad is connected and you triggered a sensor in a delay zone the keypad buzzer will be beeping In such a case you have only a limited amount of time entrance delay to enter a vali...

Page 6: ...atically in the moment when used once for arming NOTE If you press 9 in user programming level the H 915 control panel will send information about events history to the special serial interface printer which can be connected to the keypad terminals as an option Only code number 0 master code is programmed from factory the other access codes are blank 6 INSTALLER CODE Entering of INSTALLER PROGRAMM...

Page 7: ...If the premises is entered without coming through a delay entrance and a next delay loop is triggered an immediate intruder alarm will be generated 05 24Hr silent loop operates as the type 01 but it triggers the PANIC alarm 06 Instant silent loop operates as the type 02 but it triggers the PANIC alarm 07 Delay silent loop operates as the type 03 but it triggers the PANIC alarm 08 Interior instant ...

Page 8: ...rmed by both sirens The y can only be from 0 to 3 4 1y External arming control with loop 6 input If y 0 zone input 6 will work as programmed in section 1 If y 1 than zone input works as input for external arming and disarming If you close this input with E O L resistor for a moment it will have the same function as entering of a valid access code By doing this the control panel can be armed disarm...

Page 9: ...l will start in the alarm condition when the power is switch on again If there is any reason to switch the power completely off for example when you want to extend the system with an optional device we recommend to enter the installer programming level at first FACTORY DEFAULT SETTING Master Code 1234 Installer Code 1010 No other access codes programmed Zone definition 1 delay 2 next delay interio...

Page 10: ...F 3 ON ON OFF 4 OFF OFF ON 5 ON OFF ON 6 OFF ON ON 7 ON ON ON For Panic alarm y can only be 0 or 2 Panic alarm always activates Panic o Fire alarm aiways activates Fire out ES Ext Siren IS Int Siren 3 xy Alarm outputs definition x alarm default otputs programmed enter y 0 technic Relay 3 0 _ 1 fire ES IS Relay Fire 3 1 _ 2 intruder ES IS Relay 3 2 _ 3 panic Panic 3 3 _ 4 xy System option functions...