JABLOTRON
ALARMS
a.s.
Pod
Skalkou
4567/33
46601
Jablonec
n.
Nisou
Czech
Republic
www
.jablotron.com
||
|
JA-115E, JA-115E-GR, JA-115E-AN
BUS four-segment keypad with
display and RFID reader
Typ: 1KPAD2201LU
JA-115E, JA-115E-GR, JA-115E-AN
1 / 3
MLU510603
The keypad is a component of the
JABLOTRON
system. It serves
for the controlling and current system status indication. It is equipped
with four segments. Their descriptions are displayed on the LCD
display. The device should be installed by a trained technician with
a valid certificate issued by an authorised distributor.
The keypad is
compatible with following control panels JA-102K, JA-103K and
JA-107K.
It is necessary to use this manual in combination with the
JABLOTRON 100 installation and user manuals.
The keypad comprises 4 segments (1), LCD display (2), keypad
and RFID card/tag reader (4). The tilting cover (5) can be removed if
the user prefers permanent access.
Figure 1
: 1 – control buttons; 2 – LCD display;
3 – system indicator / button; 4 – keypad with RFID reader; 5 – cover;
Figure 2
: 6 – connection points of the BUS terminal; 7 – serial number;
8 – tamper contacts; 9 – locking mechanism; 10 – tab
Installation
1. Remove the mounting pad (rear part) of the keypad. If you can´t
remove it easily, open the locking mechanism, see paragraph
Keypad disassembly
.
2. In the rear part, break out the cover on the corresponding place,
push the BUS cable through the plastic base and attach it to the
selected place.
3. Connect all the BUS cable wires to the terminal (6) as follows:
a) Using a flat screwsdriver to press upper side of the terminal
b) Put the stripped wire into to correct terminal
c) Release the terminal
d) By a gentle pulling of the wire test if it´s correctly fixed
+U
– red; positive power supply pole
A
– yellow; data wire A
B
– green; data wire B
GND
– black; negative power supply pole
Notes
:
−
Connect only straight, stripped wires to the BUS terminals
(their ends only).
4. First attach the bottom edge of the keypad to the mounting pad (rear
part) of housing (align the bottom sides). Then slide the keypad
downwards, untill you hear the click of the tab (10). This will secures
the keypad against falling out of the installation pad. Then turn the
locking mechanism (9) clockwise 90° to the position where the
groove points to the symbol ). This locks the keypad in place and
engages the tamper contact.
5. Power the system on.
6. Enrollment to the system according to the type of control panel
use the recommended software or application, see the
installation manual of the control panel.
Notes:
−
Enrollment is also possible by entering its serial number (7) in
the F-Link software or using a bar code scanner. All numbers
stated under the bar code must be entered (1400-00-0000-
0001).
Keypad disassembly
On the underside of the keypad, turn the locking mechanism (9)
anticlockwise 90° untill the groove points to the symbol . Then use
a screwdriver to release the tab (10) while sliding the keypad up. The
keypad can then be easily removed from the mounting pad. (If the
mounting pad is not screwed on, use the same procedure, just slide
the mounting pad downwards against the keypad).
Setting the properties
The settings are configured by the F-Link software -
Devices
tab.
Use the
Internal settings
option on the device position. A dialogue
window will appear in which all the keypad functions can be set. The
internal settings are devided into two basic tabs:
Segments
and
Settings
.
The Segments tab:
Within the
Segments
tab, the required functions can be set for
individual segments (control of sections, indication of section status,
triggering of a panic alarm, control of PG output, indication of PG
output status, etc.).
The segment descriptions can be edited by F-Link directly by
clicking on the segment text.
Always switch the power off before
connecting the keypad to the BUS.