JA-150E Wireless keypad 

JA-10E BUS keypad 

2 / 3 

MLU25301 

Activated by pressing or authorization requirement

 – the keypad 

wakes up after pressing a button on a keypad cover 

 

or by an authorization request, for example during the entrance delay. 

 

Wake the keypad by applying an RFID card:

 Apart from opening  

or pressing the keypad cover, the keypad can wake up by applying  
an RFID card/tag. It is not recommended to enable this function  
if the keypad is surrounded by metal objects and electric wiring.  
If this function is enabled, it is necessary to check that the keypad 
does not wake up by itself. 

Unset a section by authorization only during  an entrance delay

 

– 

using an access code or an RFID tag will unset a section where  
an entrance delay has been triggered (provided the user has access 
to the section). This authorization can be used with wireless keypads 
only when they declare an entrance delay. 
WARNING: This function is not recommended when the control panel 
is configured to use a Common section. Unwanted unsetting may 
occur to all sections assigned to the Common section or it may even 
occur to the whole control panel (when pressing the Unsetting button 
is followed by authorization). 

Delayed panic

 – this function triggers a panic alarm (silent or loud) 

with an adjustable delay during which the alarm can be cancelled. 
Activation and deactivation is done by a function button configured  
to Panic or Silent panic functions. The button pressed once triggers 
the delay. Press the button the second time to cancel the delay.  
When authorization is enabled then it is required for activation and 
deactivation. The delay is adjustable from 1 to 255 seconds. 

Backlight intensity 

 

Indicators

 – Backlight intensity of indicators. 

Function buttons 

– Backlight intensity of the function buttons.  

Keypad

 – Backlight intensity of the keypad. 

Display

 –Backlight intensity of the LCD display. 

Contrast

 – LCD display contrast. 

 

A keypad configuration which complies with 
certification requirements must be selected 
from the list of System profiles in the 
Parameters tab of the F-Link SW. 

Automatic stand-by mode 

When the keypad is battery supplied it preserves energy by turning 

off the system indication and the display after keys on the keypad 
haven’t been pressed within 10 second or when the keypad cover  
is closed. However the keypad still maintains communication with  
the control panel and will for example signal entrance delay.  
The keypad will be completely active when the keypad cover  
is opened, pressed or by applying an RFID card (provided this 
function has been activated in the 

Settings

). 

Alternative power supply 

The keypad can be supplied from an external power supply 

with 12 V DC connected in +U and GND terminals. You can use  
the DE06-12 Power adaptor suitable for concealed installation. 

When the keypad is supplied externally it will communicate with 

the control panel permanently and it will indicate system statuses 
according to the selected parameters in 

Internal settings  

in the 

Devices 

tab. If the alternative power supply is used keep 

the batteries in the detector, they will provide back up in case 
the power supply is disconnected. Batteries inserted in the detector 
cannot be recharged by the external power supply. 

Changing the batteries 

The keypad automatically checks its own battery status. When 

the batteries are close to being depleted, it will inform the control 
panel that the batteries need to be replaced. They should be replaced 
within two weeks after the message appears. The control panel must 
be switched into Service mode before removing the keypad from 
the back part otherwise (otherwise a tamper alarm will be triggered). 

Note:

 

In order to make sure the keypad works correctly, 

 

we recommend using batteries supplied by the distributor or other 
quality brand lithium batteries. 

Optical indication 

System indicator: 

Continuous green light 

- Normal operation. Sections controlled  

by the keypad are OK, no faults.  

Continuous yellow light 

- Normal operation, reported faults 

 

in some of the controlled sections. You can get more detailed 
information via 

the 

LCD keypad menu after user authorization 

depending on the user access rights. 
Optical indication followed by a rotating Jablotron logo on the LCD 
keypad represents a radio communication fault between the control 
panel and the keypad  

Continuous red light 

– The keypad is in BOOT mode, used while 

upgrading firmware. 

Flashes green (2Hz) 

– Ongoing authorization during which the user 

can change the statuses of the function buttons or browse the keypad 
menu. Authorization times out after 8 seconds from the last time any 
of the buttons had been pressed or it can be cancelled by pressing 
ESC. 

Flashes yellow (8Hz)

 - Unsuccessful setting warning indication  

Flashes red (8Hz)

 - Indication of a currently triggered alarm in one  

of the sections controlled by the given keypad. The type of alarm, 
name of the section where an alarm has been triggered and  
the source of the triggered alarm are visible on the LCD keypad. 

Flashes alternately red/yellow

 - Triggered alarm with an active fault 

indication. 

Flashes alternately green/red

 – Ongoing authorization with an alarm 

memory. 

Flashes alternately green/yellow

 – Ongoing authorization with  

an active fault indication. 

Flashes yellow 2x every 2 seconds

 - Programming / Service mode. 

All control segment indication is disabled, function keys along with the 
keypad menu are unavailable for users and 

the 

Administrator. 

 

The keypad menu is only available for a service technician unless  
a PC is connected to the control panel.  

Flashes red 2x every 2 seconds

 - Alarm memory indication.  

Flashes yellow 1x every 2 seconds

 - Fault indication on a keypad 

which is in sleep mode (only valid for the EN50131-1 and Incert 
profile). 

Flashes red 1x every 2 seconds

 - Alarm memory indication  

on a keypad which is in sleep mode (only valid for the EN50131-1 and 
Incert profile). 

No indication

 – The keypad is in sleep mode.

 

Function buttons and status indicators

 – the status of the function 

buttons is simultaneously indicated by the status indicators A, B, C, D. 

Continuous green light 

- Section status is Unset or a PG output  

is OFF. 

Flashes green (4Hz)

 – Ongoing entrance delay. The control panel 

waits to be Unset. 

Continuous yellow light 

- Section status is Partially set. 

Continuous red light 

- Section status is Set or a PG output is ON. 

Flashes yellow (4Hz)

 - The control panel expects authorization when 

partially set or it reports a fault during partial setting. 

Flashes yellow (8Hz)

 - Unsuccessful setting warning indication. 

Flashes red (4Hz)

 – The control panel waits for authorization during 

setting or it reports a problem during setting. 

Flashes red (8Hz)

 - Alarm memory indication. It is indicated until  

it is cancelled. 

No light

 - Service mode or a blocked section after an alarm (after 

blocking and cancelling alarm memory indication). 

Acoustic indication 

It can be set regardless of the keypad’s optical indication and sleep 

mode. The keypad can indicate entrance/exit delay or alarm.  
During valid authorization (by a user code or RFID card), the acoustic 
indication of exit delays is suppressed. By pressing the indication 
button the keypad is muted permanently. Entrance delay and alarm 
are indicated until their time expires, unless the activation button  
is pressed. 

Keypad FW update 

The keypad supports wireless FW updating which is done 

 

in 

Service mode 

via the 

F-Link

 software. 

1. Select 

Control panel 

Æ

Æ

 Firmware update. 

You’ll see 

 

JA-150E in the dialog window. If F-Link contains newer 
firmware than the one in the keypad then it will be automatically 
offered.  

2. Pressing 

the 

OK 

button will perform update of selected devices.  

3.  After the FW update is finished, check the keypad’s internal 

settings in the 

Internal settings 

in the

 

Devices tab.

 

4.  Check the keypad’s functionality. 

Note: 

 

The mini USB connector (10) is used to update the firmware  
by connecting the keypad with a computer via a mini USB cable. 
Use this method when wireless update fails.  

 

 