background image

JABLOTRON

ALARMS

a.s.

Pod

Skalkou

4567/33

46601

Jablonec

n.

Nisou

Czech

Republic

www

.jablotron.com

||

|

JA-151P-WW Wireless PIR motion detector

JA-151P-WW Wireless PIR motion detector

1 / 2

MMN51205

The JA-151P-WW is a wireless component of the

JABLOTRON 100

system. It serves for the detection of human movement in building 
interiors. Its guaranteed detection coverage is 90° horizontally and 
detection range is 12 m. This PIR motion detector utilizes a

white lens

which provides standard immunity against white light required by the 
norm (up to 6000 lux). False alarm immunity is available in two options. 
The detector has a pulse reaction

and takes one position in the system

.

The detector should be installed by a trained technician with a valid 
certificate issued by an authorized distributor.

Installation

It’s necessary to take into consideration that there should be no 

obstacles in the detector’s view which quickly change temperature (electric 
heaters, gas appliances, etc.), which move (e.g. curtains hanging above a 
radiator, robotic vacuum cleaners) or the movement of house pets. 
Despite the detector being very immune to false alarms, it is not 
recommended to install the detector opposite windows or floodlights or in 
places with over-intense air circulation (close to ventilators, heat sources, 
air conditioning outlets, unsealed doors, etc.). There should be no 
obstacles in front of the detector obscuring its view over the guarded 
space.

Figure 1.: 1 – LED indicators, 2 – PIR lens, 3 – Hole for locking screw,

4 – Cover  tab

1. Open the detector cover by pressing the cover tab (4). Avoid 

touching the PIR sensor inside (6) – you could damage it

2. Take out the PCB – it is held by a tab in the lower part.
3. Punch through the holes for the screws and the cable in the plastic 

base. The recommended installation height is 2.5 m above the 
floor. 

4. Set the DIP switches (9) according to the requirements, see 

the

Detector settings

.

5. Insert the PCB back and proceed according to the control panel 

installation manual. Basic procedure:
a. The control panel must contain the JA-110R radio module.
b. Go to the 

F-Link

software, select the required position 

in the

Devices

window and launch the 

Enrollment mode

by clicking on the 

Enroll

option. 

c. Insert the batteries (mind the correct polarity). When the second 

battery has been inserted into the detector, an enrollment signal 
is transmitted to the control panel and the detector is enrolled 
to the selected position. The detector can be enrolled by 
entering the production code (8).

d. This is followed by a detector stabilization phase indicated with 

LED indicator (10) flashing which takes up to three minutes.

6. Close the detector cover.

Figure 2: 5 – Antenna; 6 – PIR sensor; 7 – Tamper contact; 8 – Production 

code; 9 – Setting DIP switches; 10 – Red LED indicator;

11 – The JA-191PL external tamper connector; 12 – Battery holder

Note:

The detector can be removed from the system by deleting it from 
its position in the 

Devices 

tab.

Detector internal settings

Internal settings can be configured by DIP switch on a PCB inside 

the detector 

(*factory defaults).

Immunity level: 

DIP switch no. 1 determines a level of false alarm 

immunity. The 

NORM*

level (default setting) combines basic immunity 

with a rapid reaction. The 

HIGH

level (DIP switch ON) provides 

increased immunity but the detector reaction is slower.

External tamper sensor:

DIP switch no. 2 can enable (DIP switch 

ON) /disable* the external tamper of the JA-191PL jointed bracket. 

Detector function modes

The detector can work in two modes. They are indicated by one or two 

flashes of the LED light (10) when batteries are inserted.

One flash represents 

Smartwatch*

mode. It’s determined for 

the permanent monitoring of movement in the guarded area. 
If permanent movement is detected, three reports are sent every 20 s. 
The next report is then sent after 2 minutes. If the detector does not 
detect any movement for 10 minutes, the mode with three reports every 
20 s is used again. 

Two flashes represent a 

One minute interval.

The detector enters 

standby mode for 1 minute after it has detected movement. When 
the standby mode times out, the detector wakes up and is ready to be 
triggered again.

To change the mode, press and hold the tamper contact (7) in the 

cover, insert the batteries at the same time. Release the tamper contact

3-5 seconds after the batteries insertion. The detector then flashes 

either once or twice to indicate the currently selected mode. When 
batteries are replaced the setting doesn’t change. 

Detector testing

When you close the detector cover, LED light indicates all movement 

for a period of 15 minutes and reports it to the control panel. After this 
time the detector switches to the mode which was selected during 
the battery insertion. 

Detector functions can also be checked via the 

Diagnostics

window 

in the 

F-Link

software. You can check the selected mode and immunity 

level in 

Internal settings

. This information serves as a preview and can’t

be changed by F-link software. 

Battery replacement

The system sends automatic reports when the battery is low. 

Remember to switch the system to Service mode before changing 
the batteries. It’s necessary to wait for 10 seconds or repeatedly press 
the tamper contact (7) in order to release the remaining charge before 
you insert new batteries. If you insert batteries with low energy (

”9

detected) the LED light will indicate that by flashing rapidly during 
the testing period. 

Detection characteristics

The standard lens that is supplied with the detector has a white

colour and covers an area of 90°/12 m. The area is covered by 
3 beams (curtains) – see the following figure.

The lens cannot be 

replaced by a different type of lens.

Figure 3. This detection characteristic is valid for standard PIR immunity.

Installation

accessories

JA-193PL – Detector wall holder.

Instead of installing the detector 

in a room’s corner, it’s possible to install it on a wall surface using 
a

JA-193PL

aesthetic frame which is distributed in two colours – white 

and grey. Using the frame, the detector is partially hidden under 
a plaster or plasterboard wall.

JA-191PL – PIR jointed bracket.

It is used for special placement, 

such as installation on the ceiling or at a tilted angle (higher installation 
height). The jointed bracket is a certified detector accessory having its 
own tamper contact which is to be connected to the connector inside 
the detector (11).

Reviews: