background image

The JA-152J MS II Bi-directional two-button key fob 

JA-152J MS II 

2 / 2 

MMJ23100 

Locking the keyfob 

The  remote control buttons can be locked (blocked) against 

accidental pressing. Locking is disabled by default, pressing any button 

triggers its function immediately.  

If the buttons are locked, a control panel command is sent when 

a button is pressed 2x quickly (2x per 1 s) it is also valid for the panic 

function. 

Caution:  When a reaction for pressing buttons (A+B) 

simultaneously  is set  (for example a  panic alarm or garage 

door control), it is necessary to  mind that the  action is 

performed first. 

The 

lock can be activated 

by simultaneously  pressing and holding 

the pair of buttons (A+B) until the yellow LED (1) starts flashing, usually 

in 3 s. When the yellow LED (1) is flashing release button (B) and press 

it again. Activation of the lock function is performed and confirmed by 

double flashes of the yellow LED and a double beep. After this 

confirmation release all buttons. 

The 

lock is  deactivated 

by repeating the procedure above. 

Deactivation of locking is confirmed by one flash of the yellow LED and 

one beep. 

Acoustic indication 

Acoustic indication can be completely disabled. The default is 

enabled. When any button is pressed it is followed by a short acoustic 

signal according to the table 2. 

Caution:  When a reaction for pressing buttons (A+B) 

simultaneously  is set  (for example a  panic alarm or garage 

door control), it is necessary to  mind that the  action is 

performed first. 

The 

acoustic indication

  can be disabled by simultaneous pressing 

and holding  the pair of buttons (A+B) until the yellow LED (1) starts 

flashing briefly for the second time, usually in 6 s. When the  yellow 

LED (1) flashes a second time release the button (B) and press it again. 

The acoustic indication is then disabled and confirmed by flashes of the 

yellow LED and a one beep. After this confirmation release all buttons. 

The 

acoustic indication

 can be enabled by repeating the procedure 

above. Activation is confirmed by a double flash of the yellow LED and 

a double beep. 

LED indication table 

Action 

Indication 

The press of a button is indicated by an acoustic signal (if set) followed 

by a LED flash of corresponding colour.  

The mentioned indication statuses are valid for the remote’s default 

setting. 

Unsetting 

Control 

function 

with 

confirmatio

n by LED 

1x flash of green LED  

and 2x short acoustic signals 

Setting 

1x flash of red LED 

and 1x short acoustic signal 

Partial setting 

1x flash of yellow LED 

and 1x short acoustic signal 

Unsetting after an 

alarm 

1x flash of green LED 

and 3x short acoustic signals 

Delayed panic 

Flashing of red LED 

until action is done or its 

cancelling 

Setting confirmation 

request 

Flashing of red LED 

until confirmation (max. 8 s) 

Partial setting 

confirmation request 

Flashing of yellow LED 

until confirmation (max. 8 s) 

Pressing of button with no function 

or lost communication 

Short flash of yellow LED 

1x short acoustic signal 

Low battery 

Flashing of yellow LED 

Holding the button – Copy PG 

1x short acoustic signal, 

red LED flashing for the 

duration of the button being 

pressed 

Table 2. Remote control indication 

Battery replacement 

Low battery indication is signalled on the remote control after any 

button is pressed. The action assigned  to the button is done and the 

yellow LED flashes with 3 quick beeps. Low battery information is also 

sent to the control panel. The remote still works as usual but the  RF 

range goes slowly down. Low battery indication is cancelled when 

a new battery is inserted. 

To change the battery, unscrew the 2 screws from the back plastic; 

remove the cover with the metal strut from the housing and remove the 

discharged battery. Then press any button a few times to discharge the 

rest of the energy from the capacitors and insert a new battery. 

Battery replacement DOESN´T RESET the keyfob settings nor 

the locks nor the acoustics

Don´t throw a  used battery into the trash but take it to  a suitable 

recycling station. 

Technical specifications 

Compatible with: 

FW of the JA-11xR module  

FW of the control panel LJ(MD)60416+ 

F-Link 1.4.0+

Power – 1x lithium battery 

type CR 2032 (3.0 V/0.2 Ah) 

(Power supply C type according to EN 50131-6) 

Current consumption: 

- Nominal consumption

1,1 μA

 

- Maximal consumption

33 mA 

Low battery voltage detection 

 2.2 V 

Typical battery lifetime 

approx. 2 years (10 activations/day) 

Communication frequency 

868.1 MHz, JABLOTRON protocol 

Maximum radiofrequency output (ERP) 

1.2 mW 

RF range 

approx. 100 m (line of sight) 

Dimensions 

63 x 36 x 15 mm 

Weight without the battery 

32 g 

Classification 

Security grade 2/Environmental class II 

(According to EN 50131-10) 

Environmental 

Indoor general 

Operational temperature range 

-10 °C to +40 °C

Average humidity 

75 % RH, non-condensing 

Number of unique production codes 

> 1 Million

Certification body 

Trezor Test s.r.o. (no. 3025) 

Additionaly in compliance with 

ETSI EN 300 220-1,-2, EN 50130-4, 

EN 50130-4, EN 550, EN 62368-1, EN 50581, EN 50131-1, 

EN 50131-3, EN 50131-5-3, EN 50131-6 

Can be operated according to 

ERC REC 70-03 

 

JABLOTRON ALARMS a.s. hereby declares that the 

 

JA-152J MS  II  is in a compliance with the relevant Union 

harmonisation legislation: Directives No: 2014/53/EU, 

2014/35/EU, 2014/30/EU, 2011/65/EU. The original of the 

conformity assessment can be found at www.jablotron.com - 

Section Downloads. 

Note: Although this product does not contain any harmful 

materials we suggest you return the product to the dealer or 

directly to the producer after use.  Additional  information  can 

be found  at 

www.jablotron.com

 - Section Downloads. 

Reviews: