The JA-152J MS II Bi-directional two-button key fob
JA-152J MS II
2 / 2
MMJ23100
Locking the keyfob
The remote control buttons can be locked (blocked) against
accidental pressing. Locking is disabled by default, pressing any button
triggers its function immediately.
If the buttons are locked, a control panel command is sent when
a button is pressed 2x quickly (2x per 1 s) it is also valid for the panic
function.
Caution: When a reaction for pressing buttons (A+B)
simultaneously is set (for example a panic alarm or garage
door control), it is necessary to mind that the action is
performed first.
The
lock can be activated
by simultaneously pressing and holding
the pair of buttons (A+B) until the yellow LED (1) starts flashing, usually
in 3 s. When the yellow LED (1) is flashing release button (B) and press
it again. Activation of the lock function is performed and confirmed by
double flashes of the yellow LED and a double beep. After this
confirmation release all buttons.
The
lock is deactivated
by repeating the procedure above.
Deactivation of locking is confirmed by one flash of the yellow LED and
one beep.
Acoustic indication
Acoustic indication can be completely disabled. The default is
enabled. When any button is pressed it is followed by a short acoustic
signal according to the table 2.
Caution: When a reaction for pressing buttons (A+B)
simultaneously is set (for example a panic alarm or garage
door control), it is necessary to mind that the action is
performed first.
The
acoustic indication
can be disabled by simultaneous pressing
and holding the pair of buttons (A+B) until the yellow LED (1) starts
flashing briefly for the second time, usually in 6 s. When the yellow
LED (1) flashes a second time release the button (B) and press it again.
The acoustic indication is then disabled and confirmed by flashes of the
yellow LED and a one beep. After this confirmation release all buttons.
The
acoustic indication
can be enabled by repeating the procedure
above. Activation is confirmed by a double flash of the yellow LED and
a double beep.
LED indication table
Action
Indication
The press of a button is indicated by an acoustic signal (if set) followed
by a LED flash of corresponding colour.
The mentioned indication statuses are valid for the remote’s default
setting.
Unsetting
Control
function
with
confirmatio
n by LED
1x flash of green LED
and 2x short acoustic signals
Setting
1x flash of red LED
and 1x short acoustic signal
Partial setting
1x flash of yellow LED
and 1x short acoustic signal
Unsetting after an
alarm
1x flash of green LED
and 3x short acoustic signals
Delayed panic
Flashing of red LED
until action is done or its
cancelling
Setting confirmation
request
Flashing of red LED
until confirmation (max. 8 s)
Partial setting
confirmation request
Flashing of yellow LED
until confirmation (max. 8 s)
Pressing of button with no function
or lost communication
Short flash of yellow LED
1x short acoustic signal
Low battery
Flashing of yellow LED
Holding the button – Copy PG
1x short acoustic signal,
red LED flashing for the
duration of the button being
pressed
Table 2. Remote control indication
Battery replacement
Low battery indication is signalled on the remote control after any
button is pressed. The action assigned to the button is done and the
yellow LED flashes with 3 quick beeps. Low battery information is also
sent to the control panel. The remote still works as usual but the RF
range goes slowly down. Low battery indication is cancelled when
a new battery is inserted.
To change the battery, unscrew the 2 screws from the back plastic;
remove the cover with the metal strut from the housing and remove the
discharged battery. Then press any button a few times to discharge the
rest of the energy from the capacitors and insert a new battery.
Battery replacement DOESN´T RESET the keyfob settings nor
the locks nor the acoustics
.
Don´t throw a used battery into the trash but take it to a suitable
recycling station.
Technical specifications
Compatible with:
FW of the JA-11xR module
FW of the control panel LJ(MD)60416+
F-Link 1.4.0+
Power – 1x lithium battery
type CR 2032 (3.0 V/0.2 Ah)
(Power supply C type according to EN 50131-6)
Current consumption:
- Nominal consumption
1,1 μA
- Maximal consumption
33 mA
Low battery voltage detection
≤
2.2 V
Typical battery lifetime
approx. 2 years (10 activations/day)
Communication frequency
868.1 MHz, JABLOTRON protocol
Maximum radiofrequency output (ERP)
1.2 mW
RF range
approx. 100 m (line of sight)
Dimensions
63 x 36 x 15 mm
Weight without the battery
32 g
Classification
Security grade 2/Environmental class II
(According to EN 50131-10)
Environmental
Indoor general
Operational temperature range
-10 °C to +40 °C
Average humidity
75 % RH, non-condensing
Number of unique production codes
> 1 Million
Certification body
Trezor Test s.r.o. (no. 3025)
Additionaly in compliance with
ETSI EN 300 220-1,-2, EN 50130-4,
EN 50130-4, EN 550, EN 62368-1, EN 50581, EN 50131-1,
EN 50131-3, EN 50131-5-3, EN 50131-6
Can be operated according to
ERC REC 70-03
JABLOTRON ALARMS a.s. hereby declares that the
JA-152J MS II is in a compliance with the relevant Union
harmonisation legislation: Directives No: 2014/53/EU,
2014/35/EU, 2014/30/EU, 2011/65/EU. The original of the
conformity assessment can be found at www.jablotron.com -
Section Downloads.
Note: Although this product does not contain any harmful
materials we suggest you return the product to the dealer or
directly to the producer after use. Additional information can
- Section Downloads.