background image

The JA-158P wireless outdoor PIR detector

The JA-158P wireless outdoor PIR detector

2 / 2

MMY51504

Setting up the optical part of the PIR 

detector

The above-mentioned detection characteristics apply if the detector 

is installed vertically in the guarded area. If a shorter detection range 
is required, do not tilt the detector on the joint. Use the supplied self-
adhesive mask foils:

Masking using strips of the supplied foil can also be used to avoid 

unwanted moving objects (e.g. a tree). Use the supplied protective hood 
for protection against the sun and rain.

Setting up the electronic part of the PIR 

detector

It is possible to set three levels of detector sensitivity using the switch 

on the left of the bottom PIR – the levels are marked with letters:

L

low – low sensitivity for places with false alarm risks

M

middle – medium sensitivity

H

high – high detection sensitivity

Other parameters can be set using the switches:

     normal mode

                                           

test mode

save mode 120 s

5 s

standard immunity                                      

high immunity

Fault output N.C.                          

do not set this

       do not set this                                    fault is not alarm

             LED disabled                                     

LED enabled

                          

Area coverage test

(DIP1) – the energy saving mode is not applied 

and each detectable movement is indicated by an LED. The alarm is always 
transmitted regardless of the energy saving mode settings (DIP2).

The energy saving mode

(DIP2). When the detector is activated 

and transmits the information to the control panel, it stops detecting motion

in its view for a set time. 

The activation of the LED

(DIP6) serves 

as an indication of the detector function – i.e. the area coverage. Disable the 
LED to save the batteries in ordinary operation.

Testing

When the batteries are connected, the detector needs approx. 90 seconds 

for stabilization. The LED keeps flashing all the time. Use the DIP switch 1
to commence the area coverage test. Test the correct coverage of the 
guarded area and whether the detector detects motion outside the guarded 
area. Each movement is indicated by flashing detector LED and the 
information is sent to the control panel.

When the test is finished to meet the declared battery lifetime, stop 

the area coverage test, check whether the indication LED is off and set 
the energy saving mode to 120 s.

Normal operating mode

Each time the detector is activated, the information is transmitted by 

a radio signal. When the detector cover is opened or the detector is removed 
from the bearing plate, a tamper signal is transmitted. The detector also 
regularly (every 9 minutes) transmits control signals which serve the control 
panel to check the presence and readiness of all devices in the installed 
system. 

The masking protection function

The detector has an anti-masking function – i.e. protection against 

masking of the detector´s field of sight. If an object is detected in front of the 
detector for more than three minutes, the detector sends a tamper signal. 
Three short flashes of the LED indicate masking (the LED must be enabled).
When the object has been removed, the indication (tamper signal) ceases 
after one minute. 

It is possible to set three levels of this function using the switch on the right 

of the bottom PIR – the levels are marked with letters:

HI

high – high masking detection sensitivity

STD

standard – standard masking detection sensitivity

OFF

off – function disabled

Factory settings pre-set to STD.

Replacing the batteries

The detector checks the battery status automatically. Nearly drained 

battery is reported by continuous flashing of yellow signalling LED 
on the detector (1 flash per sec) and at the same time low battery status 
is reported to the control panel. The detector remains fully functional. 
The battery should be changed as soon as possible.

The control panel must be in service mode 

before battery changing

(see the control panel installation manual). Tamper contact must be pressed 
several times after opening the cover and removing the battery to discharge 
capacitors

.

Always use CR123A (3 V, 1.4 Ah) batteries or alternatively LS(T) 

14500 (3,6 V AA) batteries. Always replace all batteries simultaneously.

Note

: Use 2x lithium batteries however if needed it is possible to use

3x batteries in to increase the detector’s lifetime.

Technical specifications

Power:

2x Lithium battery type CR123A (3.0 V/1.4 Ah)

Please note: Batteries are not included

Current consumption (nominal/maximal)

50 

μ

A/54 mA

Average battery lifetime

2 x (3 x) CR123A, approx. 3 years (4 years)*

Alternative power

2 x Lithium battery type CR14500 (AA) 3.6 V/2.45 Ah

Average battery lifetime

2 x (3 x) CR14500, approx. 3 years (4 years)*

* valid for enabled 120 s saving mode

Communication band

868.1 MHz

RF range – distance from the control panel

up to 300 m (open area)

Optex detector parameters

Detection characteristics

12 m / 85°; 94 segments

Recommended installation height

2.5 – 3.0 m

Object motion speed

0.3 – 1.5 ms

-1

Battery saving timer

adjustable 5 s or 120 s

Detector cover conformance

IP55

Max. relative humidity of the environment

95%

Operational environment according to EN 50131-1

IV 

Operating temperature range

-20 °C to +60 °C

Security grade

according to OPTEX

Complies with

ETSI EN 300 220, EN 50130-4, 

EN 55022, EN 60950-1

Weight

620 g

Can be operated according to                              

ERC REC 70-03

JABLOTRON ALARMS a.s. hereby declares that the JA-158P is in a 
compliance with the relevant Union harmonisation legislation: 
Directives No: 2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/EU. 
The original of the conformity assessment can be found at 
www.jablotron.com - Section Downloads.

Note: Although this product does not contain any harmful materials 
we suggest you return the product to the dealer or directly 
to the producer after use. 

Reviews: