background image

The JA-159P wireless outdoor PIR detector 

 

The JA-159P wireless outdoor PIR detector 

2 / 2 

MMY51801 

 

Fig. 5. 

   

The detection area angle is 90°. The direction can be adjusted 

from position A – G by rotating the detector´s plastic part. Each step 
is circumscribed. The detector lens covers the whole angle of 180° - 
therefore it does not require any adjustment.

 

You can restrict the detection angle by adhesive masking 

strips supplied with the package. This way you can eliminate 
problematic parts of the detection area. The strips are to be 
stuck on the relevant lens segment from the inner side. 

The PIR detection sensitivity can be configured by a 3-pole switch 

located under the upper sensor. The letters correspond to sensitivity 
levels as follows:  

 

L

  low – applicable to bad conditions 

M

 middle 

 

H

 high 

 

 

Other parameters can be configured using a DIP switch: 

 

 

 

 
NORM

                                         

TEST

 

120s

5s 

 

     5 s … šet

Ĝ

ící režim 

N.C.                                                  

N.O. 

LED OFF       

LED ON 

 

          on

Antimasking OFF 

Antimasking ON 

Factory settings highlighted by bold letters. 

 

 

The LED serves for PIR detector testing – checking the coverage. 

The detector always sends information to the control panel. For 
normal detector operation the LED should be turned off in order to 
save the battery. 

The power save mode can be set up by DIP switch no. 2, select 

5 s / 120 s. 

Testing (coverage test) 

 

By DIP switch no. 1, enter test mode and by DIP switch no. 4 turn 

on the LED indication. Close the detector.  Test the detection range 
of the protected area and immunity out of the protected area.  

Bear in mind the potential changing of detecting distance 

influenced by the environment.  

Each movement is indicated by LED and it sends the information to 

the control panel (can be checked by F-link software in the 
Diagnostics tab).  

We recommend turning off the indication LED when the testing 

procedure is finished. And set up the power save mode to 120s to 
get a longer battery lifetime. 

Normal operating mode 

The detector sends a radio signal about activation when it is 

triggered. In the case of tampering with the detector or tearing the 
detector off its position the detector sends a tamper signal. Every 9 
minutes status report is sent to the control panel. 

Replacing the batteries 

The detector checks its battery status automatically and if the 

batteries are running low it informs the system. The detector remains 
fully functional. The batteries should be changed as soon as possible 
(within 1 week). 
 

Before battery replacement 

the control panel has to be switched 

to service mode (see installation manual of the control panel) and 
then it is possible to open the cover of the detector. Always use 
CR123A (3V, 1500 mAh) batteries or alternatively LS(T) 14500 (3,6V 
AA) batteries.  

Note

: Always use 2x lithium batteries. If needed put 3x batteries in 

to increase the detector’s lifetime.

 

Troubleshooting

Problem 

Problem cause 

Solution 

The detector 
makes false 
intrusion 
alarms 

Lower detection area is 
unnecessarily long. 

Set the detection area 
properly. 

The detector is exposed 
to direct/reflected light 
(sun light, car light etc.). 

Remove the reflector, 
mask the area exposed to 
the reflection of light or 
change the detector 
position. 

There is a moving object 
in the area (laundry on 
the clothes-line, plants 
etc.). 

Remove the moving 
object or change the 
detector position. Or put 
the stickers on part of the 
lens to avoid detection in 
a problematical place. 

Occasionally 
no reaction 
to 
movement 

Lower detection area is 
unnecessarily short 

Set the detection area 
properly 

Sensitivity is set to low 
(L). 

Change sensitivity to 
medium (M) or high (H). 

The detector is in battery- 
save mode 

While testing operation, 
set the battery-save timer 
to 5 seconds. 

Detector 
ignores any 
movements 

Low battery 

Replace the battery 

LED indicator lights but 
there is no reaction in the 
control panel. 

The control panel is out of 
range, check the battery, 
try to reposition detector 
or control panel 

 

 

 

Fig. 6. Detector dimensions (mm) 

Technical specifications 

Power: 

2x Lithium battery CR123A (3 V, 1500mAh)

  

Average battery lifetime 

2 x (3 x) CR123A, approx. 3 years (4 years)* 

Alternative power 

2 x Lithium battery LS(T)14500 (3.6 V,AA) 

Average battery lifetime 

2 x (3 x) LS(T) 14500, approx. 3 years (4years)*  

 

*-valid for enabled 120s saving mode

 

Communication band 

868.1 MHz 

RF range – communication range 

up to 300 m (open area) 

Optex detector parameter 
Detection characteristics 

12 m / 90 °; 16 segments 

Recommended installation height 

0.8 – 1.2 m 

Object motion speed 

0.3 – 1.5 ms

-1

Battery saving timer 

adjustable 5 s or 120 s 

Operational environment according to EN 50131-1 

IV 

Security grade  

according to Optex 

Operating temperature range 

-20 °C to +60 °C 

Detector cover conformance 

IP55 

Max. relative humidity of the environment  

95 % 

Dimensions  

186 x 71.3 x 105.5 mm 

Weight 500 

Complies with 

ETSI EN 300 220, EN 50130-4,  

 

EN 55022, EN 60950-1, EN 50581 

Can be operated according to                

ERC RED 70-03 

JABLOTRON ALARMS a.s. hereby declares that the 

JA-159P

is 

in compliance with the essential requirements and other relevant 
provisions of Directive 1999/5/EC and 2011/65/EU. The original 
of the conformity assessment can be found at 

www.jablotron.com

 

- Technical Support section

.

 

Note: Although this product does not contain any harmful 
materials we suggest you return the product to the dealer or 
directly to the producer after use. For more detailed 
information visit www.jablotron.com. 

 

 

Reviews: