JA-188P outdoor wireless motion detector
JA-188P outdoor wireless motion detector
2 / 2
MKU53800
Setting up the optical part of the detector
The optical part of the detector contains two PIR sensors with non-overlapping
94 lobe detection and high false alarm and pet detection immunity.
Installation at 3.0 m
above the floor
12 m
12 m
16
m
85
o
When installing the detector 2.5m
above the floor, use the joint holder
and swivel the detector by 2.5°(one
click) upwards to achieve a 12m
detection distance.
The above-mentioned detection characteristics apply if the detector is installed
vertically in the guarded area. If a shorter detection range is required, do not tilt the
detector on the joint. Use the supplied self-adhesive mask foils:
9 m
1
USE
MASK
4 m
1+2+3
USE
MASKS
5,5 m
1+2
USE
MASKS
Masking using strips of the supplied foil can also be used to avoid unwanted
moving objects (e.g. a tree). Use the supplied protective hood for protection
against sun and rain.
The joint can be used to adjust the detector position along two axes. When
installing the detector at the height of 2.5m, swivel it by 2.5° (one click)
upwards to achieve a 12m detection range.
Setting up the electronic part of the detector
It is possible to set three levels of detector sensitivity using the switch on the
left of the bottom PIR – the levels are marked with letters:
L
low – low sensitivity for places with false alarm risks
M
middle – medium sensitivity
H
high – high detection sensitivity
Other detector parameters can be set with a switch:
normal operation
area coverage test
energy saving mode 120 s
5 s
standard detection
increased detection immunity
Keep set as shown here
Keep set as shown here
LED indication disabled
LED indication enabled
Area coverage test
(DIP1) – the energy saving mode is not applied and
each detectable movement is indicated by an LED. The alarm is always
transmitted regardless of the energy saving mode settings (DIP2).
The
energy saving mode
(DIP2) is similar to that of the JA-180P detector. When
the detector is activated and transmits the information to the control panel, it
stops detecting motion for a set time.
The activation of the LED
(DIP6)
serves as an indication of the detector function – i.e. the area coverage. The
detector always transmits information to the control panel – disable the LED to
save the batteries in ordinary operation.
Operation testing
When the batteries are connected, the detector needs approx. 90 seconds
for stabilization. The LED keeps flashing all the time. Use the switch to
commence the area coverage test. Test the correct coverage of the guarded
area and whether the detector detects motion outside the guarded area. Each
movement is indicated by a flashing detector LED and the information is
concurrently sent to the control panel.
When you have tested the correct functioning of the detector, stop the area
coverage test, check whether the indication LED is off and set the energy saving
mode to 120s. This is necessary to meet the declared battery lifetime.
Normal detector operation
Each time the sensor is activated, the information is transmitted by a radio signal.
When the detector cover is opened or the detector is removed from the bearing
plate, a tamper signal is transmitted. The detector also regularly (every 9 minutes)
transmits control signals which serve the control panel to check the presence and
readiness of all devices in the installed system.
The masking protection function
The detector has an anti-masking function – i.e. protection against masking
of the detector’s field of sight. If an object is detected in front of the detector for
more than three minutes, the detector sends a tamper signal. Three short
flashes of the LED indicate masking (the LED must be enabled). When the
object has been removed, the indication (tamper signal) ceases after one
minute.
It is possible to set three levels of this function using the switch on the right
of the bottom PIR – the levels are marked with letters:
HI
high – high masking detection sensitivity
STD
standard – standard masking detection sensitivity
OFF
off – function disabled (default setting)
This function is disabled as a default.
Checking the status of and replacing
batteries.
The detector checks battery status automatically and if the batteries are
running low, it informs the system that they need replacing. The detector
remains fully functional. The batteries should be changed as soon as possible
(within 1 week). Use 3.6 V AA batteries exclusively and always replace all
three at the same time. When the cover has been closed, the detector
switches to normal operating status.
Technical specifications
Power supply
3x type LS(T)14500 (AA 3.6 V 2 Ah) lithium batteries
Average battery lifetime
approx. 3 years (with 120 s energy saving mode)
Operating frequency
868.1 MHz
Range – distance from the control panel
up to 300 m with direct visibility
Optex detector parameters
Detection characteristics
12 m / 85° ; 94 segments
Recommended installation height
2.5 – 3.0 m
Object motion speed
0.3 – 1.5 ms
-1
Battery saving timer
adjustable 5 s or 120 s
Detector cover conformance
IP55
Max. relative humidity of the environment
95%
Operating temperature range
-20°C to +60°C
Environment class according to EN 50131-1
IV
Security grade
according to OPTEX
Weight
620 g
Comply with
ETSI EN 300220, EN 50130-4, EN 55022, EN 60950-1
Can be operated according to
ERC REC 70-03
266
99
20
5
148
JABLOTRON ALARMS a.s. hereby declares that the JA-188P is in
compliance with the essential requirements and other relevant provisions of
Directive 1999/5/EC.
The original of the conformity assessment can be found at
www.jablotron.com
- Technical Support section
Note: Although this product does not contain any harmful materials we
suggest you return the product to the dealer or directly to the producer
after use.
1234