The JA-80X communicator is a component of Jablotron systems 

of the JA-8x series. It is designed to be installed within the control 
panel housing. Main features: 

Alarm voice-reporting. 

ARC (Alarm Receiving Centre) communication. 

Remote access via a telephone keypad. 

Backup option for the JA-80Y GSM communicator. 

The JA-80X only uses the tone dialling method. 

1. 

Installation 

 

x

The  communicator  can  be  connected  to  the  control  panel’s 
digital bus via a four-cord RJ cable. Use connectors marked RS 
LINE  on  the  communicator.  Both  RS  LINE  connectors  have 
parallel  wiring,  thus  they  can  also  be  used  for  splitting  the 
control panel digital bus. 

x

Connect  the  communicator  to  a  telephone  line  via  the  cable 
supplied  with  the  package.  Use  a  socket  marked  LINE  on  the 
communicator. 

x

Additional  telephone  devices  (telephone,  facsimile  machine, 
modem  etc.)  can  be  connected  using  the  connector  marked 
“TEL”. 

x

When the control panel is in normal stand-by mode, the phone 
line and any attached device will operate as normal. 

x

The  communicator  can  only  be  connected  to  analogue  phone 
line  and  must  not  be  connected  to  a  dual  or  a  grouping 
extension-line. 

 

Note:

  The  communicator  must  be  plugged  directly  into  a 

telephone line socket. All other devices should be connected to the 
communicator output marked TEL. 
 

2. 

Alarm voice-reporting  

 
 

Depending on the type of events, the communicator is capable 

of  sending  5  assigned  alarm  reports  to  up  to  4  pre-programmed 
phone numbers. 

x

With  the  control  panel  being  in  the  unset  state,  enter  Service 
mode  by 

keying-in  *0 SC

  (SC=service  code, 

8080

  by  factory 

default) on the system keypad. 

x

Key-in the requested programming sequence(s). Any sequence 
currently being entered can be escaped from by pressing #. 

x

Completing  a  sequence  entry  is  confirmed  by  a  beep.  After 
completing all the requested sequences, 

exit Service mode by 

pressing the # key

x

Depending  on  system  configuration,  telephone  numbers  can 
also be entered in operating mode. 

2.1. 

Programming  telephone  numbers  for  voice 

reporting 

sequence 71 Mxxx  xx*0

 

 

To program tel. numbers used for voice reporting enter: 

71Mxx... xx *0 

 

where:   

is the phone number memory 1 to 4 

xx...xx 

is the desired phone number (max.16 digits) 

 

 
Special codes can be put into the phone number: 
Code :  

*

 

by

 

pressing

  

*

            

#

 by pressing  

*

8  

            3 s pause by 

pressing

 

*

6

 

 
Example: 

Entering 712 483 123 456 *0 will store the number 483 

123 456 in memory 2. 

 

To 

erase

 a number from memory M enter: 

71M*0 

where:  

M

 

is memory 1 to 4 

 

Voice reports are sent to pre-programmed phone numbers in the 

order  they  are  stored.  A  single  report  to  a  particular  tel.  number 
starts  with  the  number  being  dialled.  A  6  sec  waiting  period 
follows.  After  this  period  voice  message  No.  1  is  played  (alarm 
system  identification)  followed  by  an  event  description  message. 
This is repeated 4 times after which the communicator hangs up. 
Normally,  voice  reporting  is  not  terminated  until  after  all  the 
numbers have been reported to. However, you can stop reporting 
by alarm cancellation or by pressing the 

#

 key on the phone which 

is currently being reported to. 

If  enabled,  ARC  reporting  is  performed  prior  to  telephone  voice 

reporting. 

 
Note:

 Do not program emergency call numbers! 

As a factory default, all phone number memories are erased. 

 

2.2. 

Limited event-reporting  

 

 

 

sequence 792x

 

 
The  communicator  has  a  special  option  for  the  2

nd

  tel.  number 

such that only INTRUSION or PANIC alarms are reported to that 
number (other types of alarm events like Fire, Fault or Tamper are 
not reported).  

During the call to the 1st tel. number the user can decide whether 

the  alarm  report  should  be  also  forwarded  to  the  remaining  tel. 
numbers  or  ha  can 

terminate  further  voice  call  reporting  by 

pressing #

 on the phone keypad (e.g. in case of the false alarm). 

 

To program the feature enter: 

 

792x 

 

where:         

x=0 

only INTRUSION or PANIC alarms are reported to 
the 2

nd

 tel. number 

x=1 

all events reported to all numbers 

 
The factory default setting is

 7921 

This setting doesn't apply to transmissions to the ARC, which are 

made via voice messages. 

2.3. 

Voice message recording 

 

You can record voice messages via any phone using DTMF tone 

dialling.  First,  call  the  communicator’s  phone  number.  During  the 
dial-up period, enter 

72

 on the system keypad. The communicator 

will answer the call which is indicated by a beep. Press a key 

0

 

to

 

8

 on the phone keypad according to which of the following actions 

you wish to perform: 

 

0 – Replay all messages 
1 – Record  message  No.  1  (Alarm  reports)  –  identify  your 

alarm system (your premises) 

2 – Record message No. 2 (Intrusion) 