background image

3.   Make a call to someone who will act as a test person.
4.    Use 

56

 to scroll through 12-setting transmit volume menu 

 until your test person 

confi rms your voice is at the appropriate volume.

5.   Press OK to confi rm new setting.

The transmit volume menu is the permanent default/start position for the LCD display. After 
adjusting any of the other settings via the display, it will revert to the transmit volume menu 
position.

 

 

Important

: For USB applications, the volume settings are fi xed and need no adjustment.

 2.5.2 

Hookswitch 

selection 

The GN 9350 enables you to answer and end calls remotely by using the GN 1000 RHL, or its 
built-in electronic hookswitch (EHS) modes. EHS is only possible on certain telephone sys-
tems. In order to determine which telephones have the EHS feature enabled, please refer to our 
website www.gnnetcom.com/gn9120/ehs-setup. Please also refer to your telephone´s user 
manual for clarifi cation.

4 modes are available

GN RHL

non-EHS; works with the GN 1000 RHL

DHSG

e.g. Siemens and Elmeg desk telephones

AEI

e.g. with Tenovis desk telephones

MSH

e.g. with Alcatel desk telephones

 

 

Note:

 By default, the GN 9350 is set to the RHL interface, which also is 

the correct setting if you manually operate your handset when answer-
ing/ending calls as described in the Guide for basic set-up and use.

To select the appropriate interface:
1.    Use 

34

 to locate the hookswitch selection menu 

 

 on 

base 

display.

2.   Use 

56

 to select one of the 4 interfaces from the menu.

3.   Press OK to confi rm the interface.

 

 

Note

: To use the DHSG, AEI or MSH function, connect the connec-

tion cord (accessory) to your desk telephone and the AUX port of 
the GN 9350. 

  2.5.3 Range/power selection

Your headset offers 3 range/power modes (Normal, Low and Very Low). The Normal mode 

6

Summary of Contents for GN9330 - Headset - Over-the-ear

Page 1: ...97 High Street Egham Surrey TW20 9HG United Kingdom Tel 44 0 1784 220140 Fax 44 0 1784 220141 GN Netcom Inc 77 Northeastern Boulevard Nashua NH 03062 USA Tel 800 826 4656 Tel 1 603 598 1100 Fax 1 603...

Page 2: ...arly marked GN 9350 GN 9330 GN 9330 USB to which products they concern When the feature does not apply it will simply have a wire frame box and no grey fill i e GN 9350 GN 9330 GN 9330 USB 1 Product i...

Page 3: ...4 6 Switching a call from desk telephone handset to headset 13 4 7 New master headset pairing to base 13 5 Use with DECT cordless telephones 14 6 Replacing battery pack GN Netcom accessory 14 6 1 Add...

Page 4: ...USB Desk telephone connectivity VoIP USB connectivity GN 1000 RHL enabled Electronic hookswitch enabled Display for set up Adjustable range Sound refinement DSP Conference call On line indicator conne...

Page 5: ...ou want to use your VoIP application as default calling media press the USB button for 5 seconds If you want to change it back again press the Telephone button for 5 seconds GN 9350 GN 9330 GN 9330 US...

Page 6: ...Press the OK button to confirm a specific choice value within the 5 different menus A star beside a selected choice value indicates the current setting Default start position The LCD display is always...

Page 7: ...e enabled please refer to our website www gnnetcom com gn9120 ehs setup Please also refer to your telephone s user manual for clarification 4 modes are available GN RHL non EHS works with the GN 1000...

Page 8: ...rmal Bass and Fixed Switch These two sections are separated by a blank line It is possible to choose one mode in each of the two sections Your headset offers 3 treble bass modes Treble Normal and Bass...

Page 9: ...h NIOSH standards and EU health and safety codes of 85 dB A The TT4 protection level is compliant with pertinent Australian recommendation Important In some jurisdictions applicable regulations or law...

Page 10: ...quality of incoming calls by removing impurities transmitted with the signal such as background noise from your caller s environment 3 Wearing styles Your headset offers headband neckband and ear hoo...

Page 11: ...s means the volume con trol is pushed up to increase the volume and pushed down to decrease the volume If you change the wearing ear of the headset you may also want to change the orientation of the v...

Page 12: ...pending on whether the call is coming via the desk phone telephone or via VoIP USB After the call it will revert to the default mode you selected earlier The initial factory set mode is the telephone...

Page 13: ...icipant is now terminated from the conference call GN 9350 GN 9330 GN 9330 USB 4 4 Emergency calling via VoIP Your headset supports quicker emergency calling via VoIP applications softphone If the hea...

Page 14: ...adset 1 Remove the headset from base or if already out press the headset s talk button This establishes a link The headset s link indicator will start flashing and the call will be switched to the hea...

Page 15: ...ight for 2 seconds to indicate successful pairing Your headset is now ready to use with your cordless telephone Consult your cordless telephone s user manual for using your headset with your cordless...

Page 16: ...dio and visual indicators The headset and base have audio and visual indicators that represent various functions associated with setting up and using the product GN 9350 GN 9330 GN 9330 USB 7 1 Headse...

Page 17: ...indicator Base talk button Lit when in telephone mode and flashing when linked up USB mode button s indicator Base talk button Lit when in USB mode and flashing when linked up Mute functionality indi...

Page 18: ...t Then call a friend and adjust your headset s microphone as described in the Guide for basic set up and use For setting information on your telephone system please also refer to www gnnetcom com gn93...

Page 19: ...iquids into any button sockets receptors or other openings Avoid exposing the product to rain Children and product packaging The packaging including plastic bags and wrapping parts are not toys for ch...

Reviews: