background image

MODELS:
23680-4003  12V DC 
23680-4103  24V DC

COMMERCIAL DUTY

WATER

PUPPY

FEATURES:

Continuous rated, medium duty pumps for
bilge and  general purpose use.

z

ISO 8846 MARINE (Ignition protection).

z

ISO 8849 MARINE (Bilge pump standard).

z

Small 

bilge debris present no problem to 

these bronze bodied, flexible impeller 
pumps.

z

Simple design means fewer wearing 
parts.

z

32 lpm (6.5 UK gpm) output @ 3m (10ft) 
head.

z

Self priming to 1.2m (4 ft).

INSTALLATION INSTRUCTIONS

:

Jabsco Water Puppy can be mounted on any flat
surface. Fit the pump  in a dry, well ventilated
position where there is full access for service. If
installed in a vertical position the motor must be
above the pump head. Use the rubber grommets
provided to minimise vibration, do not overtighten the
mounting screws. 

Secure 25mm (1”) id hose either direct to the
discharge ports or to ½” BSP male threaded fittings
using stainless steel hose clamps. Use spiral
reinforced hose (with a smooth internal bore) that will
not collapse under suction, or rigid or semi rigid
pipework systems. The pipework must be compatible
with the liquid being pumped. Pipe runs should be
kept as straight and short as possible, avoiding rising
and dipping over obstructions. Fit a strainer on the
inlet hose to prevent larger debris from entering the
pump.

WIRING INSTRUCTIONS

Make all electrical connections in dry locations,
connections in humid environments should be sealed
to prevent corrosion. Protect the circuit with a
correctly rated fuse or circuit breaker in the orange
positive (+) lead as close as possible to the power
source.  Connect the black motor wire to the negative
(-) battery terminal.  Inadequate voltage at the motor
terminals when the pump is running (not less than
10% below rated    voltage at full load) due to partially
discharged       batteries or insufficient cable size may
result in   blowing fuses, failure to start or poor pump
performance.

WARNING:

If the fuse fails

repeatedly do not fit a heavier fuse or
bridge the fuse terminals with silver
paper or metal wire. Failure to observe
this instruction may result in a fire
hazard due to overheating of cables.

WARNING: 

All marine pumps

discharging overboard must be
installed with the overboard discharge
well above both static and heeled
waterlines.

m

ft

lpm

UK gpm

2

7

35

7.7

3

10

32

7

4

13

30

6.6

6

20

25

5.5

WATER PUPPY PERFORMANCE

TOTAL HEAD

WATER PUPPY

Approximate performance for new pump,

running water at 20°C with fully charged battery

WARNING:

Do not use any Jabsco

pump for petrol, petroleum products or
any products with a flash point below
37°C (98°F), explosion or death may
occur.