CONFIDENTIAL
PROJECT NAME
| date
项目名称
|
日期
20
Operation Instruction
–technical parameter
PROJECT NAME
| date
项目名
称
|
日期
CONFIDENTIA
L
20
P 1 7
0~99
65
Automatic induction presser foot sensor setting (between the
maximum and minimum value
of the 02C parameter display)
P 1 8
1~120
35
Stitch balance for start back tacking No.1(Pull in compensation)
P 1 9
1~120
20
Stitch balance for start back tacking compensation
release
P 2 2
0~50
8
Needle compensate position switch interval
P 2 4
0~1024
80
Trimming point of pedal
P 2 5
1~120
35
Stitch balance for end back tacking
P 2 6
1~120
20
Stitch balance for end back tacking
P 2 7
0~2
1
presser foot induction model
(
0-2
)
0
:
swicth off
,
1
:
after trimming
presser foot lifter
,
2
:
presser foot lifter before and after trimming
P 3 0
0~31
0
Feedforward torque of
motor: 0: normal
functions 1-31:
feedforward torque level
P 3 1
10~199
50
Trimming afterburner coefficient (motor afterburner)
P 3 2
1~500
400
Thread clamp solenoid full open time (ms
)