CONFIDENTIAL
PROJECT NAME
| date
项目名称
|
日期
28
Troubleshooting
error
code
Code
meaning
solution
Err-01
Hardware
overcurrent
1, turn off the power, restart 2, check the voltage is normal
low pressure 176V high pressure 264V 3, turn the hand wheel
to see whether the mechanical parts stuck 4, check the motor
plug 5, restore the factory, test the motor angle 6,replace
the control box
Err-02
Software
overcurrent
Err-03
System undervoltage
Err-04
Excessive shutdown
Err-05
Run overpressure
Err-06
Electromagnet
circuit failure
1, check the plug, the pin is off 2, unplug the solenoid
plug to see if the error is still 3, replace the
electromagnet 4, replace the control box
Err-07
Current detection
circuit failure
1、reset the factory 2、replace the control box
Err-08
Motor stall
1, turn the hand wheel to see if the mechanical parts stuck
2, check the motor plug
3, reset the factory, test the motor angle 4, replace the
motor 5, replace the encoder 6, replace the control box